Evaluates NO formation models in an F-class gas turbine, suggesting effective emission prediction methods.
Accurate prediction of NO emissions is important for the development of low-emission gas turbine combustors. This study evaluates several NO formation models for a 78 MW F-class gas turbine using a decoupled post-processing framework. Steady RANS simulations were performed with a partially premixed flamelet/PDF combustion model. Thermal NO, prompt NO, the N2O intermediate pathway, and turbulence–chemistry interaction were assessed at 50% and 100% load. Thermal NO was the dominant pathway and showed strong load dependence. Using partial equilibrium for O radicals increased outlet NO by 16.46% at 50% load and 43.69% at 100% load. Including partial-equilibrium OH further increased NO by 8.67% at 50% load but had little effect at full load. Prompt NO remained on the order of 10−3 ppm. The N2O pathway and turbulence–chemistry interaction also affected the prediction, especially at full load. The selected model was further compared with field measurements during load ramping and pilot-ratio variation. Most load-ramping predictions agreed with measurements within 18%. The results demonstrate the applicability of the proposed framework for engineering NO emission prediction while also identifying limitations under transitional operating conditions.
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: