Key result
In patients with severe aortic stenosis undergoing TAVI, preserved versus reduced left ventricular ejection fraction did not affect overall all-cause mortality.
Why the study?
The echocardiographic predictors of 30-day and 1-year outcomes after TAVI in patients with preserved or reduced LVEF had not been clearly identified.
Cohort (n=618)
No
In patients undergoing TAVI for severe aortic stenosis, LVEF does not predict mortality, but echocardiographic markers of right ventricular dysfunction and elevated filling pressures (TAPSE, sPAP, E/E') independently predict mortality in those with preserved LVEF.
Answers are grounded in this paper and cite their sources.
Echocardiographic markers of diastolic pressure and RV function may aid risk stratification after TAVI in preserved LVEF; leaves open whether they guide decisions or apply to reduced LVEF.
AIMS: Transcatheter aortic valve implantation (TAVI) has emerged as the treatment of choice for many patients with severe symptomatic aortic stenosis. We sought to identify the echocardiographic predictors of 30-day and 1-year outcomes after TAVI in patients with preserved or reduced left ventricular ejection fraction (LVEF). METHODS: This single-centre study included 618 aortic stenosis patients (mean age 82 ± 6 years, 47.1% male; 74.8% LVEF > 50%) who underwent balloon-expandable TAVI between July 2009 and October 2018 in our hospital. All patients completed at least 6 months of follow-up by medical history review or telephone interview (median 24, quartiles 12-42 months). The primary endpoint was all-cause death. RESULTS: All-cause mortality rate was 5.2% (LVEF > 50%: 4.3% vs. LVEF ≤ 50%: 7.7%, p = 0.141) at 30 days and 15.4% (LVEF > 50%: 14.7% vs. LVEF ≤ 50%: 17.3%, p = 0.443) at 12 months post TAVI. Overall all-cause mortality rate was 45.1% (LVEF > 50%: 44.6% vs. LVEF ≤ 50%: 46.8%, p = 0.643). Mean survival time post TAVI was 51 months [95% CI (48; 55)]. In TAVI patients with LVEF > 50%, multivariate Cox regression analysis revealed several independent predictors for increased risk of death after adjusting for echocardiographic and clinical covariates: TAPSE (≤ 17 vs. > 17 mm, HR 1.528, p = 0.016) and sPAP (> 30 vs. ≤ 30 mmHg, HR 1.900, p = 0.002) for overall mortality, E/E' septal for 30-day mortality (> 21 vs. ≤ 21, HR 14.462, p = 0.010) and 12-month mortality (> 21 vs. ≤ 21, HR 1.881, p = 0.026). In TAVI patients with LVEF ≤ 50%, no independent echocardiographic predictors for outcome could be identified. CONCLUSIONS: LVEF is not a predictor of short- and long-term mortality after TAVI. In patients with preserved LVEF, left ventricular filling pressure (E/E´), systolic pulmonary artery pressure (sPAP), and TAPSE are echocardiographic risk factors for increased mortality post TAVI.
No takes yet. Share an insight, caveat, or question.
Sokalski et al. (2024) conducted a cohort in Severe aortic stenosis (n=618). Preserved left ventricular ejection fraction (LVEF > 50%) vs. Reduced left ventricular ejection fraction (LVEF ≤ 50%) was evaluated on All-cause death (p=0.643). In patients with severe aortic stenosis undergoing TAVI, preserved versus reduced left ventricular ejection fraction did not affect overall all-cause mortality.
Synapse has enriched 10 related papers. Consider them for comparative context: