Key result
Elevated SPAP > 60 mm Hg linked to ~7.7-fold higher 30-day mortality after TAVI.
Why the study?
To investigate whether preoperative echocardiographic evaluation of ventricular function, particularly right ventricular systolic and diastolic parameters including speckle-tracking analysis, could help predict 30-day mortality after TAVI.
Does preoperative echocardiographic evaluation of ventricular function, especially right ventricular parameters, predict 30-day mortality after TAVI?
Cohort (n=227)
Yes
Does preoperative echocardiographic evaluation of ventricular function, especially right ventricular parameters, predict 30-day mortality after TAVI?
Clinical parameters and severe pulmonary hypertension, rather than detailed right ventricular echocardiographic indices, are the main predictors of early mortality after TAVI.
Objectives: To investigate whether preoperative echocardiographic evaluation of ventricular function, especially right ventricular systolic and diastolic parameters including speckle-tracking analysis, could aid in the prediction of 30-day mortality after transcatheter aortic valve implantation (TAVI) in patients with aortic stenosis. Methods: This is a prospective observational cohort study including 227 patients accepted for TAVI at the University Hospital of North Norway and Oslo University Hospital from February 2010 through June 2013. All patients underwent preoperative transthoracic echocardiography with retrospective speckle-tracking analysis. Primary endpoint was all-cause 30-day mortality. Results: All-cause 30-day mortality was 8.7 % (n = 19). Independent predictors of 30-day mortality were systolic pulmonary arterial pressure (SPAP) > 60 mm Hg (HR: 7.7, 95% CI: 1.90 to 31.3), heart failure (HR: 2.9, 95% CI: 1.1 to 7.78), transapical access (HR: 3.8, 95% CI: 1.3 to 11.2), peripheral artery disease (HR: 6.0, 95% CI: 2.0 to 18.0) and body mass index (HR: 0.73, 95% CI: 0.61 to 0.87). C-statistic for the model generated was 0.91 (95% CI: 0.85 to 0.98). Besides elevated SPAP, no other echocardiographic measurements were found to be an independent predictor of early mortality. Conclusion: Except for elevated systolic pulmonary artery pressure, our data suggests that clinical rather than echocardiographic parameters are useful predictors of 30-day mortality after TAVI.
No takes yet. Share an insight, caveat, or question.
Kjønås et al. (2019) conducted a cohort in Severe symptomatic aortic stenosis (n=227). Systolic pulmonary arterial pressure (SPAP) > 60 mm Hg vs. SPAP < 30 mm Hg was evaluated on All-cause 30-day mortality (HR 7.7, 95% CI 1.90-31.3, p=0.004). Elevated systolic pulmonary arterial pressure > 60 mm Hg was an independent predictor of 30-day all-cause mortality after TAVI (HR 7.7), whereas other echocardiographic measurements of ventricular function were not.