Key result
M-mode derived MAPSE measurements demonstrated better inter- and intraobserver reliability compared to B-mode lateral MAPSE, and its reproducibility was unaffected by image quality.
Cross-Sectional (n=284)
Single-blind
No
M-mode derived MAPSE is a highly reproducible and robust echocardiographic parameter for assessing left ventricular function in children, independent of image quality.
Answers are grounded in this paper and cite their sources.
MAPSE reproducibility in children remains unproven for practice; leaves open need for validation across image qualities.
BACKGROUND: Mitral annular plane systolic excursion (MAPSE) is an increasingly used echocardiography technique to assess left ventricular (LV) function. However, reproducibility and dependence on echocardiographic image quality for MAPSE in pediatric patients have not been studied to date. METHODS: We analyzed 284 transthoracic echocardiograms performed on consecutive normotensive children without structural heart disease (mean age 12.6±3.1 years, 50.4% female). B-mode and M-mode derived MAPSE measurements were performed and analyzed regarding inter- and intraobserver reliability and the influence of echocardiographic image quality. RESULTS: Overall, MAPSE measurements were highly reproducible with only minor bias. Both inter- and intraobserver reliability were significantly better for M-mode derived MAPSE (p<0.001). Echocardiographic image quality did not significantly influence M-mode MAPSE reproducibility (p>0.235). In contrast, B-mode lateral MAPSE was significantly better reproducible in optimal image quality (-0.07±1.04) when compared to suboptimal echocardiographic images (0.42±1.59, p<0.001). Moreover, poor quality images yielded significantly lower M-mode MAPSE values (14.3±2 mm) than near-optimal (15.2±1.9 mm, p<0.001) or optimal images (15.1±2.2 mm, p = 0.006). CONCLUSION: Echocardiographic image quality essentially has a negligible effect on MAPSE reproducibility and measurements. Consequently, MAPSE is a robust echocardiographic parameter with convincing reproducibility for the assessment of LV function in children-even in patients with substandard imaging conditions.
No takes yet. Share an insight, caveat, or question.
Hensel et al. (2018) conducted a cross-sectional in Healthy children (n=284). M-mode and B-mode echocardiography (MAPSE) was evaluated on Inter- and intraobserver reliability of MAPSE measurements (p=<0.001). M-mode derived MAPSE measurements demonstrated better inter- and intraobserver reliability compared to B-mode lateral MAPSE, and its reproducibility was unaffected by image quality.
Synapse has enriched 10 related papers. Consider them for comparative context: