Why the study?
Does controlled Valsalva maneuver pressure and duration affect the quantification of right-to-left shunt by contrast transcranial Doppler in stroke patients with PFO?
Does controlled Valsalva maneuver pressure and duration affect the quantification of right-to-left shunt by contrast transcranial Doppler in stroke patients with PFO?
Controlled Valsalva maneuver pressure is crucial for reproducible right-to-left shunt assessment by contrast transcranial Doppler in PFO, whereas arterial blood gas measurement lacks sensitivity.
Answers are grounded in this paper and cite their sources.
Standardized VM pressure may enhance cTCD reproducibility for PFO shunts; leaves open prospective validation and ABG alternatives.
BACKGROUND AND PURPOSE: A right-to-left shunt can be identified by contrast transcranial Doppler ultrasonography (c-TCD) at rest and/or after a Valsalva maneuver (VM) or by arterial blood gas (ABG) measurement. We assessed the influence of controlled strain pressures and durations during VM on the right-to-left passage of microbubbles, on which depends the shunt classification by c-TCD, and correlated it with the right-to-left shunt evaluation by ABG measurements in stroke patients with patent foramen ovale (PFO). METHODS: We evaluated 40 stroke patients with transesophageal echocardiography-documented PFO. The microbubbles were recorded with TCD at rest and after 4 different VM conditions with controlled duration and target strain pressures (duration in seconds and pressure in cm H2O, respectively): V5-20, V10-20, V5-40, and V10-40. The ABG analysis was performed after pure oxygen breathing in 34 patients, and the shunt was calculated as percentage of cardiac output. RESULTS: Among all VM conditions, V5-40 and V10-40 yielded the greatest median number of microbubbles (84 and 95, respectively; P<0.01). A significantly larger number of microbubbles were detected in V5-40 than in V5-20 (P<0.001) and in V10-40 than in V10-20 (P<0.01). ABG was not sensitive enough to detect a shunt in 31 patients. CONCLUSIONS: The increase of VM expiratory pressure magnifies the number of microbubbles irrespective of the strain duration. Because the right-to-left shunt classification in PFO is based on the number of microbubbles, a controlled VM pressure is advised for a reproducible shunt assessment. The ABG measurement is not sensitive enough for shunt assessment in stroke patients with PFO.
No takes yet. Share an insight, caveat, or question.
Devuyst et al. (2004) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: