Assessment of lung effective transverse relaxation time (T(2)*) may play an important role in the detection of structural and functional changes caused by lung diseases such as emphysema and chronic bronchitis. While T(2)* measurements have been conducted in both animals and humans at 1.5 T, studies on human lung at 3.0 T have not yet been reported. In this work, ultrashort echo time imaging technique was applied for the measurement and comparison of T(2)* values in normal human lungs at 1.5 T and 3.0 T. A 2D ultrashort echo time pulse sequence was implemented and evaluated in phantom experiments, in which an eraser served as a homogeneous short T(2)* sample. For the in vivo study, five normal human subjects were imaged at both field strengths and the results compared. The average T(2)* values measured during free-breathing were 2.11(±0.27) ms at 1.5 T and 0.74(±0.1) ms at 3.0 T, respectively, resulting in a 3.0 T/1.5 T ratio of 2.9. Furthermore, comparison of the relaxation values at end-expiration and end-inspiration, accomplished through self-gating, showed that during normal breathing, differences in T(2)* between the two phases may be negligible.
No takes yet. Share an insight, caveat, or question.
Yu et al. (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: