Key result
A semiautomatic segmentation procedure correctly classified an average of about 90% of voxels with an average border mismatch lower than 1.5 voxels (1.2 mm) compared to manual segmentation.
Why the study?
Does a semiautomatic watershed segmentation procedure accurately delineate the left atrium and pulmonary veins from cardiac CT images in AF patients compared to manual segmentation?
Does a semiautomatic watershed segmentation procedure accurately delineate the left atrium and pulmonary veins from cardiac CT images in AF patients compared to manual segmentation?
A semiautomatic watershed segmentation method accurately extracts the left atrium and pulmonary veins from cardiac CT images, facilitating anatomical modeling for AF treatment.
Semiautomatic LA/PV segmentation may aid AF ablation planning; leaves open prospective validation before clinical adoption.
The delineation of left atrium (LA) and pulmonary veins (PVs) anatomy from high resolution images holds importance for atrial fibrillation (AF) investigation and treatment. In this study, a semiautomatic segmentation procedure for LA and PVs inner surface from contrast enhanced CT data was developed. The procedure consists of a three dimensional marker controlled watershed segmentation applied to the external morphological gradient, followed by variable threshold surface extraction from the original intensity image. A preliminary anisotropic non-linear filtering was implemented to improve the S/N ratio of CT images. The performance of segmentation was evaluated on cardiac CT scans of 12 AF patients both qualitatively and quantitatively. The qualitative evaluation by expert radiologist assessed the segmentation as overall successful in all patients and capable of extracting both the LA body and the connected vascular trees. The quantitative validation, by computing discrepancy measures with respect to a manually segmented gold standard, indicated an average of about 90% of voxels correctly classified and an average border mismatch lower than 1.5 voxels (1.2 mm). The accurate extraction of the inner LA-PVs walls provided by this method, along with the minimal required human intervention, should facilitate the use of anatomical atrial models for the non-pharmacological treatment of AF.
No takes yet. Share an insight, caveat, or question.
Cristoforetti et al. (2007) studied Atrial fibrillation (n=12). Semiautomatic segmentation procedure (marker controlled watershed segmentation) vs. Manually segmented gold standard was evaluated on Voxel classification accuracy and average border mismatch. A semiautomatic segmentation procedure correctly classified an average of about 90% of voxels with an average border mismatch lower than 1.5 voxels (1.2 mm) compared to manual segmentation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: