. Many of these examples have relied on static culture conditions, which result in diffusion-limited environments and cells experiencing pericellular hypoxia. Perfusion-based systems can alleviate pericellular hypoxia and other cell stresses by continually exposing the cells to fresh medium. These perfusion systems are common in microfluidic and organ-on-chip devices supporting cells as monolayer cultures or as 3D constructs. Here, we introduce a continuous flow delivery system, which uses parts readily produced with 3D printing to provide a self-contained culture platform in which cells in paper or other scaffolds are exposed to fresh (flowing) medium. We demonstrate the utility of this device with examples of cells maintained in single cell-laden scaffolds, stacks of cell-laden scaffolds, and scaffolds that contain monolayers of endothelial cells. These demonstrations highlight some possible experimental questions that can be enabled with readily accessible culture materials and a perfusion-based device that can be readily fabricated.