Key result
Infrahepatic IVC clamping did not significantly reduce bleeding during hepatectomy (233 vs. 285 ml; P=0.474) or total blood loss (499 vs. 584 ml; P=0.567) compared with nonclamping.
RCT (n=85)
Stratified by age, indocyanine green retention rate at 15 minutes, operative procedure, and number of tumors
Answers are grounded in this paper and cite their sources.
BACKGROUND: The success of hepatectomy can be associated with intraoperative blood loss because massive blood loss causes a poor prognosis. This study was designed to evaluate the effect of infrahepatic inferior vena cava (IVC) clamping on the bleeding amount during hepatectomy. METHODS: Eighty-five patients scheduled to undergo hepatic resection were randomly assigned to the IVC clamping or an IVC nonclamping group according to age, indocyanine green retention rate at 15 minutes, operative procedure, and number of tumors by prospective, randomized method. All analyses were compared by Mann-Whitney U test. RESULTS: Forty-three patients were assigned to the IVC clamping group and 42 to the nonclamping group (IVC clamping group vs. non-clamping): total blood loss (499 vs. 584 ml; p = 0.567), amount of bleeding during hepatectomy (233 vs. 285 ml; p = 0.474), amount of bleeding during hepatectomy/area of dissection (4.9 vs. 6.6 ml/cm(2); p = 0.63), CVP difference (-3 cmH(2)O vs. -1 cmH(2)O; p < 0.01), and diameter of the right hepatic vein (-2.2 cm vs. 0; p < 0.01). CONCLUSIONS: Although we had speculated that infrahepatic IVC clamping would reduce blood loss during hepatectomy, we failed to demonstrate any beneficial effects in this clinical setting with low CVP.
No takes yet. Share an insight, caveat, or question.
Kato et al. (2008) conducted an RCT in Hepatic resection (hepatectomy) (n=85). Infrahepatic inferior vena cava (IVC) clamping vs. IVC nonclamping was evaluated on Amount of bleeding during hepatectomy (ml) (p=0.474). Infrahepatic IVC clamping did not significantly reduce bleeding during hepatectomy (233 vs. 285 ml; P=0.474) or total blood loss (499 vs. 584 ml; P=0.567) compared with nonclamping.
Synapse has enriched 10 related papers. Consider them for comparative context: