Key result
The 3D mapping system improved the acute success rate of catheter ablation to 100% compared to 61% with the conventional fluoroscopy approach.
Why the study?
Posteroseptal accessory pathways associated with coronary sinus diverticulum present a rare challenge for ablation, and this study compared the safety and efficacy of the conventional approach versus a 3D mapping system.
Does a 3D mapping system improve procedural success and reduce complications compared to conventional fluoroscopy in patients undergoing catheter ablation of posteroseptal APs associated with CS diverticulum?
Cohort (n=24)
No
Does a 3D mapping system improve procedural success and reduce complications compared to conventional fluoroscopy in patients undergoing catheter ablation of posteroseptal APs associated with CS diverticulum?
The use of a 3D mapping system for catheter ablation of posteroseptal APs associated with CS diverticulum significantly reduces procedure and fluoroscopy times and improves acute success rates compared to conventional fluoroscopy.
Answers are grounded in this paper and cite their sources.
May inform ablation strategy selection in rare CS diverticulum cases; leaves open need for prospective efficacy comparisons.
Background Posteroseptal accessory pathways (APs) associated with coronary sinus (CS) diverticulum present a rare and challenge for ablation. This study aimed to compare the safety and efficacy of conventional approach and three-dimensional (3D) mapping system in the catheter ablation. Methods and Results This was a retrospective study of all patients (from January 2013 to July 2022) who underwent catheter ablation of posteroseptal AP associated with CS diverticula in our center. Patients who underwent catheter ablation using the traditional fluoroscopy method were included in the Conventional method group (n = 13). Patients who underwent catheter ablation using the 3D mapping method were included in the 3D mapping group (n = 11). Clinical characteristics, ablation procedure and outcomes were recorded and analyzed between the two groups. Out of 669 patients with posteroseptal APs, 24 of them (3.6%) were associated with CS diverticula. All patients in both groups successfully completed the electrophysiological study. In the Conventional method group, two patients experienced complications, and two patients had recurrence. However, no patients suffered from complications or recurrence during follow-up. The procedure time and fluoroscopy time in the Conventional method group were significantly longer than those in the 3D mapping method group. Conclusions The 3D mapping method is much safer and more effective than the conventional method in the catheter ablation of posteroseptal APs associated with CS diverticula.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2023) conducted a cohort in Posteroseptal accessory pathways associated with coronary sinus diverticulum (n=24). Three-dimensional (3D) mapping system vs. Conventional fluoroscopy approach was evaluated on Acute success rate of catheter ablation (p=0.02079). The 3D mapping system improved the acute success rate of catheter ablation to 100% compared to 61% with the conventional fluoroscopy approach.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: