Answers are grounded in this paper and cite their sources.
Background/Objectives: Corrosion resistance of dental alloys, indicated by metal ion release, is a significant concern. The aim of this study was to investigate the impact of various sandblasting methods on the corrosion resistance of Co-Cr-W alloy samples in an artificial saliva solution. Materials and Methods: Co-Cr-W samples, obtained by additive manufacturing (selective laser melting) and subjected to different processes, were evaluated using electrochemical corrosion tests on potentiostat equipment in Carter–Brugirard artificial saliva. All measurements were conducted at a temperature of 37 °C. The morphology of the samples was analyzed using scanning electron microscopy to highlight changes in roughness and the effects of the electrolyte solution on the surface of the samples. Results: The corrosion current density values decreased as surface processing increased, dropping from an average of 38.5 μA/cm2 in non-sandblasted samples (group A) to 0.74 μA/cm2 in samples sandblasted with both Al2O3 and glass particles (group C), while the corrosion rate of group A (434.8 mm/year) was significantly higher than that of group C (8.08 mm/year). Conclusions: The results demonstrated different behaviors between sandblasted and non-sandblasted samples, which could be attributed to surface morphology differences influencing the corrosion process.
No takes yet. Share an insight, caveat, or question.
Baciu et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: