Key result
Electrospun gelatin-chitosan polyurethane demonstrated a mean cell retention rate of 80% under physiological flow conditions, outperforming PGA/PLA and bovine pericardium.
Why the study?
Does electrospun gelatin-chitosan polyurethane improve cell retention compared to PGA/PLA and bovine pericardium in ovine endothelial cells?
Does electrospun gelatin-chitosan polyurethane improve cell retention compared to PGA/PLA and bovine pericardium in ovine endothelial cells?
Electrospun gelatin-chitosan polyurethane demonstrates superior cell retention under shear stress compared to traditional materials, highlighting its potential for tissue-engineered heart valves.
Answers are grounded in this paper and cite their sources.
Should not yet alter valve scaffold selection; leaves open translation of electrospun materials to clinical tissue-engineered valves.
Native heart valve leaflets are subjected to continuous pulsatile and homodynamic forces and can be as thin as 300 μm. For a proper function of the valve the materials selected for the leaflets need to be biocompatible, robust, flexible, and have comparable mechanical properties to the natural ones. In this paper, biocompatibility and cell retention ability for gelatin–chitosan polyurethane (PU), polyglycolide (PGA)/PLA and collagen-coated bovine pericardium were examined and their mechanical properties were tested. Endothelial cells, isolated from ovine carotid arteries were seeded onto these materials and exposed to a range of shear-stresses for a period of 1–3 h. The findings indicated that throughout the exposure time and the shear-stress range tested, a mean cell retention rate of 80% was obtained in the gelatin–chitosan PU group. However, for PGA/PLA and pericardium groups it was found that as the exposure time of shear-stress increased, a significant cell reduction was observed. Noticeably for all the range of physiological flow conditions tested, the electrospun gelatin–chitosan PU demonstrated good biocompatibility and cell retention properties and could be potentially used as a biomaterial for tissue engineering of heart valves.
No takes yet. Share an insight, caveat, or question.
Wong et al. (2010) studied Tissue engineering of heart valves. Gelatin-chitosan polyurethane (PU) vs. Polyglycolide (PGA)/PLA and collagen-coated bovine pericardium was evaluated on Cell retention rate. Electrospun gelatin-chitosan polyurethane demonstrated a mean cell retention rate of 80% under physiological flow conditions, outperforming PGA/PLA and bovine pericardium.
Synapse has enriched 10 related papers. Consider them for comparative context: