Key result
ECG signal processing using wavelet transforms and neural networks achieved a success rate of 97.305% for estimating systolic blood pressure and 95.65% for diastolic blood pressure.
Why the study?
Does a signal processing methodology using wavelet transforms and neural networks accurately estimate blood pressure from ECG signals?
Observational (n=20)
Does a signal processing methodology using wavelet transforms and neural networks accurately estimate blood pressure from ECG signals?
Answers are grounded in this paper and cite their sources.
A novel signal processing methodology using neural networks can successfully estimate systolic and diastolic blood pressure directly from ECG signals.
Blood pressure (BP) and the electrocardiographic (ECG) signal, or electrical signal of the heart, are physical measurements that provide insight into the behavior of the cardiac system. This paper presents a novel methodology, where for the first time the relationship between BP and ECG signal is shown. Initially, to perform this study, a signal sampling of ECG signals was performed on 20 patients: eighteen healthy, between 17 and 26 years old, and two with normal BP between 50 and 78 years old. Powerlab equipment was used to record the ECG signal, with electrodes used to capture the heart signal through the lead. Once the signal samples were obtained, the R and T waves in particular were studied with the aim of reading the systolic and diastolic blood pressure separately. In order to obtain the BP with the ECG signals, we used a wavelet transform to identify the R waves and T waves, and then to perform segmentation on the signal and extract the systole and diastole portions from the original signal. Following this procedure, neural networks were applied in order to have a system with systolic and diastolic pressure values based on the ECG signals. This application led to a total success rate of 97.305% for systole and 95.65% for diastole. In conclusion, this article can be said to demonstrate the existence of a relationship between BP and ECG signals.
No takes yet. Share an insight, caveat, or question.
Estrada et al. (2014) conducted an observational in Healthy / Normal Blood Pressure (n=20). ECG signal processing with wavelet transform and neural networks was evaluated on Success rate for estimating systolic and diastolic blood pressure. ECG signal processing using wavelet transforms and neural networks achieved a success rate of 97.305% for estimating systolic blood pressure and 95.65% for diastolic blood pressure.
Synapse has enriched 10 related papers. Consider them for comparative context: