Key result
A multivariable shock score stratified ICD patients into a high annual risk of appropriate shocks (10% per year in the upper quintile) versus a low risk (1.8% per year in the lower two quintiles).
Why the study?
Does a multivariable diagnostic strategy predict appropriate shock versus competing mortality in ICD patients?
Cohort (n=635)
Does a multivariable diagnostic strategy predict appropriate shock versus competing mortality in ICD patients?
A multivariable diagnostic strategy, particularly including EP stimulation, effectively differentiates the risk of appropriate ICD shocks from competing mortality in ICD patients.
BACKGROUND AND OBJECTIVE: We prospectively investigated combinations of risk stratifiers including multiple EP diagnostics in a cohort study of ICD patients. METHODS: For 672 enrolled patients, we collected history, LVEF, EP study and T-wave alternans testing, 24-h Holter, NT-proBNP, and the eGFR. All-cause mortality and first appropriate ICD shock were predefined endpoints. RESULTS: The 635 patients included in the final analyses were 63 ± 13 years old, 81% were male, LVEF averaged 40 ± 14%, 20% were inducible at EP study, 63% had a primary prophylactic ICD. During follow-up over 4.3 ± 1.5 years, 108 patients died (4.0% per year), and appropriate shock therapy occurred in n = 96 (3.9% per year). In multivariate regression, age (p < 0.001), LVEF (p < 0.001), NYHA functional class (p = 0.007), eGFR (p = 0.024), a history of atrial fibrillation (p = 0.011), and NT-pro-BNP (p = 0.002) were predictors of mortality. LVEF (p = 0.002), inducibility at EP study (p = 0.007), and secondary prophylaxis (p = 0.002) were identified as independent predictors of appropriate shocks. A high annualized risk of shocks of about 10% per year was prevalent in the upper quintile of the shock score. In contrast, a low annual risk of shocks (1.8% per year) was found in the lower two quintiles of the shock score. The lower two quintiles of the mortality score featured an annual mortality <0.6%. CONCLUSIONS: In a prospective ICD patient cohort, a very good approximation of mortality versus arrhythmic risk was possible using a multivariable diagnostic strategy. EP stimulation is the best test to assess risk of arrhythmias resulting in ICD shocks.
No takes yet. Share an insight, caveat, or question.
Bergau et al. (2018) conducted a cohort in ICD patients (n=635). Multivariable risk prediction was evaluated on All-cause mortality and first appropriate ICD shock. A multivariable shock score stratified ICD patients into a high annual risk of appropriate shocks (10% per year in the upper quintile) versus a low risk (1.8% per year in the lower two quintiles).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: