Key result
Recent technologies and ergonomic designs aim to reduce ionizing radiation exposure and occupational injuries for patients and interventional cardiac electrophysiologists.
Ongoing development of radiation reduction technologies and ergonomic planning are crucial to minimize exposure and prevent occupational injuries in the EP laboratory.
This is the authors' abstract. We don't add key points for this paper.
PURPOSE OF REVIEW: Risks associated with exposure to ionizing radiation in patients undergoing electrophysiology procedures and interventional cardiac electrophysiologists performing these procedures are a serious concern. Strategies to reduce radiation exposure are of obvious importance. In addition, interventional cardiac electrophysiologists have to perform procedures wearing heavy lead protection for prolonged periods, making them prone to cervical and lumbar spinal injuries. RECENT FINDINGS: Recently developed technologies, such as low-exposure radiographic imaging, novel radiographic imaging protection systems, nonfluoroscopic mapping systems using image integration, and remote catheter manipulation systems have been successful in reducing ionizing radiation exposure in the electrophysiology laboratory. The efficacy and safety of these technologies are being evaluated in clinical trials. In addition, economic analyses are being performed to evaluate these novel systems. The use of nonweight-bearing radiation protection devices and ergonomic design of the electrophysiology laboratory aim to reduce the incidence of occupational injuries in interventional cardiac electrophysiologists. SUMMARY: There is need for ongoing development and evaluation of new technologies to minimize exposure to ionizing radiation during electrophysiologic procedures. In addition, ergonomic planning of the electrophysiology laboratory and training of interventional cardiac electrophysiologists are crucial to occupational injury prevention.
Answers are grounded in this paper and cite their sources.
Encourages evaluation of radiation-sparing tools in EP labs; leaves open prospective validation of safety gains.
No takes yet. Share an insight, caveat, or question.
Nair et al. (2015) conducted a review in Radiation exposure and occupational injuries in electrophysiology procedures. Radiation safety and ergonomic technologies was evaluated. Recent technologies and ergonomic designs aim to reduce ionizing radiation exposure and occupational injuries for patients and interventional cardiac electrophysiologists.
Synapse has enriched 10 related papers. Consider them for comparative context: