Key result
The cross-sectional area of the brachial artery computed from longitudinal ultrasound images was 27% lower than the area measured from transverse images, likely due to transducer pressure compression.
Why the study?
Does feed-forward active contour segmentation in transverse view improve the consistency of brachial artery vasomotion measurements compared to longitudinal view?
Cross-Sectional (n=45)
No
Does feed-forward active contour segmentation in transverse view improve the consistency of brachial artery vasomotion measurements compared to longitudinal view?
Feed-forward active contour is a robust algorithm for brachial artery vasomotion segmentation, with transverse imaging offering more consistent measurements than longitudinal imaging.
Answers are grounded in this paper and cite their sources.
Transverse ultrasound may yield more consistent brachial artery measurements than longitudinal; leaves open effects on vasomotion protocols.
PURPOSE: To use feed-forward active contours (snakes) to track and measure brachial artery vasomotion on ultrasound images recorded in both transverse and longitudinal views; and to compare the algorithm's performance in each view. METHODS: Longitudinal and transverse view ultrasound image sequences of 45 brachial arteries were segmented by feed-forward active contour (FFAC). The segmented regions were used to measure vasomotion artery diameter, cross-sectional area, and distention both as peak-to-peak diameter and as area. ECG waveforms were also simultaneously extracted frame-by-frame by thresholding a running finite-difference image between consecutive images. The arterial and ECG waveforms were compared as they traced each phase of the cardiac cycle. RESULTS: FFAC successfully segmented arteries in longitudinal and transverse views in all 45 cases. The automated analysis took significantly less time than manual tracing, but produced superior, well-behaved arterial waveforms. Automated arterial measurements also had lower interobserver variability as measured by correlation, difference in mean values, and coefficient of variation. Although FFAC successfully segmented both the longitudinal and transverse images, transverse measurements were less variable. The cross-sectional area computed from the longitudinal images was 27% lower than the area measured from transverse images, possibly due to the compression of the artery along the image depth by transducer pressure. CONCLUSIONS: FFAC is a robust and sensitive vasomotion segmentation algorithm in both transverse and longitudinal views. Transverse imaging may offer advantages over longitudinal imaging: transverse measurements are more consistent, possibly because the method is less sensitive to variations in transducer pressure during imaging.
No takes yet. Share an insight, caveat, or question.
Cary et al. (2014) conducted a cross-sectional in Healthy (no atherosclerotic disease) (n=45). Transverse ultrasound imaging with FFAC segmentation vs. Longitudinal ultrasound imaging with FFAC segmentation was evaluated on Cross-sectional area of the brachial artery (27% lower, p=12 x 10^-07). The cross-sectional area of the brachial artery computed from longitudinal ultrasound images was 27% lower than the area measured from transverse images, likely due to transducer pressure compression.