Why the study?
Does sedation reduce oxygen consumption in children undergoing cardiac catheterization?
Does sedation reduce oxygen consumption in children undergoing cardiac catheterization?
Sedation significantly reduces oxygen consumption in children undergoing cardiac catheterization, necessitating simultaneous measurement of oxygen consumption and blood sampling for accurate cardiac output calculation using the Fick principle.
May bias Fick cardiac output estimates in sedated children; leaves open need for simultaneous measurement validation.
A study of oxygen consumption following sedation was performed in cardiovascular patients between 1 month and 5½ years of age. Oxygen consumption fell in all 17 subjects during cardiac catheterization (average fall 34%). Four of these children underwent a second study with similar sedation but without catheterization, and all demonstrated a fall in oxygen consumption (average fall 25.9%). This drop was particularly marked in the younger children. The change in oxygen consumption following sedation followed a roughly consistent pattern, reaching a minimum in ½ to 2 hours (generally shortly after the cardiac catheter was introduced into a blood vessel) and returning to control levels as blood was sampled and the procedure was completed. Thus, when using cardiac catheterization and the Fick principle to calculate cardiac output, simultaneous measurement of oxygen consumption and blood sampling is essential to obtain accurate results in the sedated child.
No takes yet. Share an insight, caveat, or question.
Baum et al. (1967) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: