Key result
Percutaneous mitral valve repair with the PASCAL system achieved 90% technical success and reduced mitral regurgitation to grade ≤2 in 97% of patients at 8.7 months.
Why the study?
Short and mid-term safety and efficacy of the PASCAL system for percutaneous mitral valve repair in an all-comer population with severe mitral regurgitation needed investigation.
Is percutaneous mitral valve repair using the PASCAL system feasible, safe, and effective in reducing mitral regurgitation and improving functional status at mid-term follow-up in an unselected, real-world all-comer population with severe mitral regurgitation?
Cohort (n=41)
No
Is percutaneous mitral valve repair using the PASCAL system feasible, safe, and effective in reducing mitral regurgitation and improving functional status at mid-term follow-up in an unselected, real-world all-comer population with severe mitral regurgitation?
Answers are grounded in this paper and cite their sources.
In a real-world all-comer cohort with severe mitral regurgitation and severely impaired LV function (including anatomies beyond EVEREST criteria), transcatheter mitral valve repair with the PASCAL system demonstrated high procedural success (90%) and durable mid-term MR reduction (≤2+ in 97% at 8.7 months), mostly requiring only a single device (86%).
AIMS: We investigated short and mid-term safety and efficacy of the PASCAL system for percutaneous mitral valve repair (PMVr) in severe mitral regurgitation (MR) in an all-comer population. METHODS AND RESULTS: In the first consecutive 41 patients undergoing PMVr using the PASCAL system in our centre, procedural success and safety were assessed. Efficacy in improving MR and functional class were evaluated. Median patient age was 74 years, 58.5% were male patients, and median European System for Cardiac Operative Risk Evaluation Score II was 5.1%. All patients suffered from severe MR with 59% functional MR, 29% degenerative MR, and 12% of mixed aetiology MR. The technical success rate was 90%, limited by four cases where PASCAL implantation was aborted due to a prohibitive mitral gradient. On average, 1.16 PASCAL devices per patient were implanted. All patients successfully implanted with a PASCAL device were discharged with MR grade ≤ 2 and 79% with MR grade ≤ 1. Mean follow-up was 8.7 ± 4.9 months. Ninety-seven per cent of patients remained at MR ≤ 2 at follow-up, which translated into a significantly improved New York Heart Association functional class as well as a significant reduction of systolic pulmonary artery pressure and brain natriuretic peptide levels. The procedure-related rate for major adverse events was 3%. Neither early nor late single-leaflet detachment was found. In one patient, air embolism occurred, resulting in modification of the PASCAL instructions for use. CONCLUSIONS: Percutaneous mitral valve repair using PASCAL in a real-world, all-comer population was feasible and safe, resulting in a significant mid-term reduction of MR with persistent clinical improvement.
No takes yet. Share an insight, caveat, or question.
Schlegel et al. (2021) conducted a cohort in Severe mitral regurgitation (functional, degenerative, or mixed aetiology) (n=41). Percutaneous mitral valve repair (PMVr) using the PASCAL transcatheter mitral repair system was evaluated on Sustained reduction of mitral regurgitation to MR grade ≤ 2 at mid-term follow-up (along with MVARC technical success of 90% and device success of 87%) (p=<0.0001). Percutaneous mitral valve repair with the PASCAL system achieved 90% technical success and reduced mitral regurgitation to grade ≤2 in 97% of patients at 8.7 months.
Synapse has enriched 10 related papers. Consider them for comparative context: