Key result
A user-independent, real-time algorithm successfully recognized the carotid artery in 100% of 2,149 longitudinal B-mode ultrasound images from 100 subjects.
The introduced real-time algorithm successfully recognized the carotid artery in all processed longitudinal B-mode ultrasound images, facilitating automated arterial delineation.
Answers are grounded in this paper and cite their sources.
Supports feasibility of automated carotid recognition in ultrasound; leaves open prospective validation before clinical adoption.
Automatic segmentation of the arterial lumen from ultrasound images is an important task in clinical diagnosis. Carotid artery recognition, the first task in lumen segmentation, should be performed in a fully automated, fast, and reliable way to further facilitate the low-level task of arterial delineation. In this paper, a user-independent, real-time algorithm is introduced for carotid artery localization in longitudinal B-mode ultrasound images. The proposed technique acts directly on the raw image, and exploits basic statistics along with anatomical knowledge. The method's evaluation and parameter value optimization were performed on a threefold cross validation basis. In addition, the introduced algorithm was systematically compared with another algorithm for common carotid artery recognition in B-mode scans, separately for multi-frame and single-frame data. The data sets used included 2,149 images from 100 subjects taken from three different institutions and covering a wide range of possible lumen and surrounding tissue representations. Using the optimized values, the carotid artery was recognized in all the processed images in both multi-frame and single-frame data. Thus, the introduced technique will further reinforce automatic segmentation in longitudinal B-mode ultrasound images.
No takes yet. Share an insight, caveat, or question.
Sifakis et al. (2014) studied Carotid artery recognition in ultrasound images (n=100). User-independent, real-time algorithm for carotid artery localization vs. Another algorithm for common carotid artery recognition was evaluated on Carotid artery recognition. A user-independent, real-time algorithm successfully recognized the carotid artery in 100% of 2,149 longitudinal B-mode ultrasound images from 100 subjects.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: