Key result
The use of non-fluoroscopic systems during radiofrequency catheter ablation for supraventricular tachycardia significantly reduced mean fluoroscopy time (10.8 vs 32.0 minutes) compared to conventional fluoroscopy.
Why the study?
Does non-fluoroscopic navigation system guidance reduce fluoroscopy time, radiation dose, and procedure time in patients undergoing radiofrequency catheter ablation for supraventricular tachycardia?
Cohort (n=200)
No
Does non-fluoroscopic navigation system guidance reduce fluoroscopy time, radiation dose, and procedure time in patients undergoing radiofrequency catheter ablation for supraventricular tachycardia?
Absolute Event Rate: 10.8% vs 32%
p-value: p=<0.001
The use of non-fluoroscopic navigation systems for radiofrequency catheter ablation of supraventricular tachycardia significantly reduces radiation exposure and fluoroscopy time without compromising procedural success or safety.
Supports minimizing radiation exposure in SVT ablation; leaves open randomized confirmation of safety and efficacy.
INTRODUCTION: The use of non-fluoroscopic systems (NFS) to guide radiofrequency catheter ablation (RFCA) for the treatment of supraventricular tachycardia (SVT) is associated with lower radiation exposure. This study aimed to determine if NFS reduces fluoroscopy time, radiation dose and procedure time. METHODS: We prospectively enrolled patients undergoing RFCA for SVT. NFS included EnSiteTM NavXTM or CARTO® mapping. We compared procedure and fluoroscopy times, and radiation exposure between NFS and conventional fluoroscopy (CF) cohorts. Procedural success, complications and one-year success rates were reported. RESULTS: A total of 200 patients over 27 months were included and RFCA was guided by NFS for 79 patients; those with atrioventricular nodal reentrant tachycardia (AVNRT), left-sided atrioventricular reentrant tachycardia (AVRT) and right-sided AVRT were included (n = 101, 63 and 36, respectively). Fluoroscopy times were significantly lower with NFS than with CF (10.8 ± 11.1 minutes vs. 32.0 ± 27.5 minutes; p < 0.001). The mean fluoroscopic dose area product was also significantly reduced with NFS (NSF: 5,382 ± 5,768 mGy*cm2 vs. CF: 21,070 ± 23,311 mGy*cm2; p < 0.001); for all SVT subtypes. There was no significant reduction in procedure time, except for left-sided AVRT ablation (NFS: 79.2 minutes vs. CF: 116.4 minutes; p = 0.001). Procedural success rates were comparable (NFS: 97.5% vs. CF: 98.3%) and at one-year follow-up, there was no significant difference in the recurrence rates (NFS: 5.2% vs. CF: 4.2%). No clinically significant complications were observed in both groups. CONCLUSION: The use of NFS for RFCA for SVT is safe, with significantly reduced radiation dose and fluoroscopy time.
No takes yet. Share an insight, caveat, or question.
See et al. (2016) conducted a cohort in Supraventricular tachycardia (n=200). Non-fluoroscopic systems (NFS) vs. Conventional fluoroscopy (CF) was evaluated on Fluoroscopy time (minutes) (p=<0.001). The use of non-fluoroscopic systems during radiofrequency catheter ablation for supraventricular tachycardia significantly reduced mean fluoroscopy time (10.8 vs 32.0 minutes) compared to conventional fluoroscopy.