Key result
2D echocardiography successfully visualizes transseptal needle positioning to allow safe manipulation without aortic root puncture.
Why the study?
Inadvertent puncture of the intrapericardial aorta is a serious complication of transseptal catheterization, and two-dimensional echocardiography provides spatial resolution of the aorta and interatrial septum.
Does two-dimensional echocardiography improve visualization and safety during transseptal cardiac catheterization?
Observational (n=13)
Does two-dimensional echocardiography improve visualization and safety during transseptal cardiac catheterization?
Answers are grounded in this paper and cite their sources.
Two-dimensional echocardiography is a useful adjunct to fluoroscopy during transseptal catheterization that may improve procedural safety and prevent complications such as aortic puncture.
Inadvertent puncture of the intrapericardial aorta is a serious complication of transseptal catheterization. Two-dimensional echocardiography allows delineation and spatial resolution of the aorta and interatrial septum. Thirteen patients underwent transseptal catheterization with simultaneous monitoring of needle and catheter position using fluoroscopy and two-dimensional echocardiography. The interatrial septum was demonstrated in the short-axis and four chamber views, and clearly separated from the ascending aorta. The transseptal needle and catheter were visualized by echocardiography while the needle tip was manipulated into the fossa ovalis avoiding puncture of the aortic root. In some cases, under pressure from the needle tip just before puncture, the interatrial septum appears to bulge toward the left atrium. Saline solution contrast echocardiography helped to confirm the needle position in the right atrium, and in the left atrium after puncture. These data suggest that two-dimensional echocardiography is a useful adjunct to fluoroscopy during transseptal catheterization that may improve its safety and prevent complications.
No takes yet. Share an insight, caveat, or question.
Kronzon et al. (1984) conducted an observational in Patients undergoing transseptal cardiac catheterization (n=13). Two-dimensional echocardiography was evaluated on Visualization of needle and catheter position. Two-dimensional echocardiography successfully visualized the transseptal needle and catheter in 13 patients, allowing safe manipulation into the fossa ovalis without aortic root puncture.
Synapse has enriched 10 related papers. Consider them for comparative context: