Key result
Correlation coefficients between heparin levels by anti-Xa assay and PTT or ACT were widely variable in neonates undergoing ECMO.
Why the study?
Does heparin level by anti-factor Xa assay correlate with PTT or ACT in neonates undergoing ECMO?
Observational (n=21)
Does heparin level by anti-factor Xa assay correlate with PTT or ACT in neonates undergoing ECMO?
Answers are grounded in this paper and cite their sources.
In neonates undergoing ECMO, PTT and ACT therapeutic ranges corresponding to heparin levels are highly variable, suggesting no single laboratory test is sufficient for anticoagulation management.
The objective was to identify the usefulness of heparin level by anti-factor Xa (anti-Xa) assay vs activated partial thromboplastin time (PTT) or activated clotting time (ACT) in neonates undergoing extracorporeal membrane oxygenation (ECMO). A retrospective record review of 21 patients in the neonatal intensive care unit (mean ECMO initiation age, 2 days; range, 0-4 days; male/female ratio, 1:1) undergoing ECMO from 2006 to 2008 was performed. Linear regression correlations between anti-Xa, PTT, and ACT were determined by extrapolating PTT and ACT therapeutic ranges that corresponded with the ECMO heparin target range of 0.3 to 0.6 U/mL. Pearson correlation coefficients between heparin levels and PTT (-0.903 to 0.984), PTT less than 40 seconds after correction using PTT-heparinase (-0.903 to 1.000), and ACT (-0.951 to 0.891) in this patient population were widely variable. Inconsistency of PTT and ACT therapeutic ranges corresponding to heparin levels of 0.3 to 0.6 U/mL prompts a multifactorial approach to ECMO management because no single laboratory test can be used to determine appropriate anticoagulation management.
No takes yet. Share an insight, caveat, or question.
Khaja et al. (2010) conducted an observational in Neonates undergoing extracorporeal membrane oxygenation (ECMO) (n=21). Anti-factor Xa (anti-Xa) assay, PTT, and ACT was evaluated on Linear regression correlations between anti-Xa, PTT, and ACT. Correlation coefficients between heparin levels by anti-Xa assay and PTT or ACT were widely variable in neonates undergoing ECMO.
Synapse has enriched 10 related papers. Consider them for comparative context: