Answers are grounded in this paper and cite their sources.
Findings in patients who underwent computed tomography (CT)-guided percutaneous needle biopsy (n = 131) of lung are described. In those in whom the needle traversed aerated lung, complications developed in 51% (40 of 79). The rate of pneumothorax was 46% (36 of 79). In those in whom the needle did not traverse aerated lung (n = 52), minor hemoptysis in one patient (2%) was the only complication (P less than .0001). When a percutaneous CT-guided lung biopsy needle does not traverse aerated lung, the likelihood of complication appears to be slight.
No takes yet. Share an insight, caveat, or question.
Haramati et al. (1991) studied this question.