Key result
Blood group O linked to ~2.4-fold higher bleeding risk in LVAD patients.
Observational (n=111)
Answers are grounded in this paper and cite their sources.
Demonstrates that blood group O is associated with increased bleeding risk in left ventricular assist device patients, highlighting the role of reduced von Willebrand factor.
Background The ABO blood group system is linked to hemostasis via its relationship with von Willebrand factor (VWF) and factor VIII (FVIII). In the current study, we investigated the association of the ABO system with clinical outcomes as well as VWF and platelet function in patients with left ventricular assist devices (LVADs). Methods Bleeding and thromboembolic complications were assessed in 111 patients during 1 year after LVAD implantation. In 67 LVAD patients, VWF antigen, VWF activity, VWF ristocetin cofactor, VWF collagen-binding, and FVIII activity were assessed. Platelet surface P-selectin and activated glycoprotein IIb/IIIa were determined by flow cytometry, and soluble P-selectin was measured with an enzyme-linked immunoassay. Platelet aggregation was assessed by light transmission and impedance aggregometry. Results Thirty-six patients (32.4%) experienced a bleeding and 22 patients (19.8%) a thromboembolic event. In univariate analyses, patients with blood group O had numerically more bleeding complications and less thromboembolic events as compared to patients with blood group non-O (both p ≥ 0.05). After multivariable adjustment, blood group O was significantly associated with a higher risk of bleeding (hazard ratio 2.42 [95% confidence interval 1.03–5.70], p = 0.044) but not linked to thromboembolic complications. Conclusion Patients with blood group O had significantly lower levels of VWF and FVIII (all p < 0.05), whereas P-selectin expression in response to thrombin-receptor activating peptide and soluble P-selectin were higher as compared to patients with blood group non-O (both p < 0.05). LVAD patients with blood group O are at an increased bleeding risk, potentially due to lower VWF and FVIII levels.
No takes yet. Share an insight, caveat, or question.
Tscharre et al. (2022) conducted an observational in Left ventricular assist device (LVAD) implantation (n=111). Blood group O vs. Blood group non-O was evaluated on Bleeding complications (HR 2.42, 95% CI 1.03-5.70, p=0.044). Blood group O was associated with a higher risk of bleeding than non-O blood groups in LVAD patients.
Synapse has enriched 10 related papers. Consider them for comparative context: