Answers are grounded in this paper and cite their sources.
Live cells function within narrow limits of physiological temperature ( T ) and O 2 and metabolite concentrations. We have designed a cell-permeable T -sensitive fluorescence lifetime-based nanoprobe based on lipophilic sulforhodamine, which stains 2D and 3D cell models, shows cytoplasmic localization, and has a robust response to T (∼0.037 ns/K). Subsequently, we evaluated the probe and fluorescence lifetime imaging microscopy (FLIM) technique for combined imaging of T and O 2 gradients in metabolically active cells. We found that in adherent 2D culture of HCT116 cells intracellular T and O 2 are close to ambient values. However, in 3D spheroid structures having size >200 μm, T and O 2 gradients become pronounced. These microgradients can be enhanced by treatment with mitochondrial uncouplers or dissipated by drug-induced disaggregation of the spheroids. Thus, we demonstrate the existence of local microgradients of T in 3D cell models and utility of combined imaging of O 2 and T .
No takes yet. Share an insight, caveat, or question.
Jenkins et al. (2016) studied this question.