Demonstrates improved lubrication and load-bearing in hydrogel coatings, indicating enhanced implant performance.
Hydrogel coatings, featuring high water content and excellent biocompatibility, represent a highly promising strategy for the surface functionalization of biomedical implants. However, developing a hydrogel coating that simultaneously integrates high mechanical strength, superior lubrication performance, and robust interfacial anchoring on implant substrates remains a long-standing critical challenge. Inspired by the hierarchical anisotropic structure of natural articular cartilage, we report a gradient double-network (GDN) hydrogel coating based on a polydopamine–gelatin–carboxymethyl cellulose (CMC)–tannic acid (TA) system. The fully physically cross-linked GDN hydrogel coating was fabricated via a facile three-step strategy: (i) polydopamine (PDA) pretreatment of the implant substrates; (ii) formation of the primary preorganized physical network through low-temperature refrigeration, where abundant phenolic hydroxyl groups of TA formed multiple hydrogen bonds and hydrophobic interactions; (iii) establishment of the secondary physical cross-linked network through directional diffusion of aluminum ions (Al3+), where Al3+ formed ionic coordination complexes with the −COO– groups on CMC chains via in situ ion exchange. This fabrication process generates a gradient in cross-linking density through the thickness across the coating: the dense bottom layer endows the coating with exceptional load-bearing capacity (a compressive modulus of 455 kPa), while the loosely cross-linked, highly hydrated top layer ensures efficient lubrication. Furthermore, the incorporation of the nonionic surfactant Tween 80 enables the coating to achieve an ultralow coefficient of friction (CoF = 1.9 × 10–3) without additional lubricants. Furthermore, the coating exhibits robust interfacial bonding through multiple interfacial interactions, delivering a high adhesion energy of 285 ± 11 J m–2. This biomimetic gradient structure synergistically breaks the inherent trade-off among load-bearing capacity, lubrication performance, and interfacial adhesion, providing a universal and facile strategy for the surface functionalization of articular cartilage implant materials.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: