Answers are grounded in this paper and cite their sources.
Cu can be extracted with Bi(DDC)₃ or Zn(DDC)₂ in chloroform from aqueous solutions up to 5 N in HF, HF₄B, H₂SO₄, H₃PO₄, HClO₄, up to 3 N in HCl, and up to 1 N in HNO₃. In most cases, extraction times of 1 min are sufficient for quantitative extraction. Washing of the organic phase without loss of Cu is possible with NaOH or with water. Cu can be back-extracted into an aqueous phase by HNO₃, KMnO₄ or Tl³⁺. Extractions from 0.1 N H₂SO₄ or from a citrate buffer with Bi(DDC)₃ are selective except for Au³⁺, Tl³⁺, Hg²⁺, and Ag⁺; these elements can be eliminated by first extracting the sample with Ni(DDC)₂. Application of the Bi(DDC)₃ reagent to solutions of neutron activated geological or plant material yielded samples containing ⁶⁴Cu in excellent radiochemical purity with one single extraction. Detailed procedures and results of the analysis of standard materials are given.