Recrystallized, polycrystalline tungsten was self-damaged by 20 MeV tungsten ions up to a calculated damage dose in the damage peak of 0.23 dpa. The time to acquire this dose and hence the average damaging dose rate was varied from 6 × 10-3 to 4 × 10-6 dpa/s, the latter coming close to the damage dose rate expected from fusion neutrons in future devices such as ITER and DEMO. One series was conducted at 295 K and one at 800 K to check for possible effects of defect evolution at elevated temperature. The created damage was decorated afterwards with a deuterium plasma at low ion energy of < 15 eV and low flux of 6 × 1019 D/m2 until saturation to derive a measure for the defect density that can retain hydrogen isotopes. 3He nuclear reaction analysis (NRA) was applied to derive the deuterium depth profile and the maximum concentration in the damage peak. Neither for the 295 K nor for the 800 K series a variation in deuterium retention with damage dose rate was found.