Key result
DDDR pacing improves exercise time by ~1.1 minutes and well-being versus VVIR pacing.
Why the study?
Atrial tachyarrhythmias have been a relative contraindication to dual-chamber pacing, prompting the development of mode-switching algorithms to prevent rapid tracking.
Does DDDR pacing with mode switching improve exercise time and patient-reported outcomes compared to DDDR without mode switching or VVIR pacing in patients with paroxysmal atrial tachyarrhythmias and heart block?
RCT (n=48)
crossover
Does DDDR pacing with mode switching improve exercise time and patient-reported outcomes compared to DDDR without mode switching or VVIR pacing in patients with paroxysmal atrial tachyarrhythmias and heart block?
Absolute Event Rate: 8.1% vs 7%
p-value: p=<0.01
In patients with paroxysmal atrial tachyarrhythmias and heart block, DDDR pacing with mode switching improves exercise capacity and patient-reported well-being compared to conventional DDDR or VVIR pacing.
OBJECTIVES: We sought 1) to compare three pacing modalities-DDDR with mode switching (DM), DDDR with conventional upper rate behavior (DR) and VVIR (VR)-in patients with a history of atrial tachyarrhythmias, and 2) to assess the efficacy of six mode-switching algorithms. BACKGROUND: A history of atrial tachyarrhythmias has been a relative contraindication to dual-chamber pacing. Several mode-switching algorithms have recently been developed to prevent rapid tracking of atrial tachyarrhythmias. METHODS: Forty-eight patients (mean age 64 years, 58% male) with a history of atrial tachyarrhythmias and heart block had a DM pacemaker implanted. Pacemakers were programmed to DM, DR and VR modes for 4 weeks each in a randomized crossover design. All subjects used a patient-activated electrocardiographic (ECG) recorder throughout the study and additionally underwent ambulatory ECG monitoring and a treadmill exercise test in each mode. They completed three symptom questionnaires at the end of each pacing period. At the end of the study, patients chose their preferred pacing period. RESULTS: DM was significantly better than VR mode objectively (exercise time DM 8.1 min, VR 7.0 min, p < 0.01) and subjectively (perceived well-being DM 69, VR 51, p < 0.001; functional class DM 2.2, VR 2.5, p < 0.05; subjective symptom score DM 21.2, VR 26.8, p = 0.01). Patient-perceived well-being was significantly better with DM than with DR mode (DM 69, DR 60, p = 0.02). DM mode was the preferred pacing period (DM 51%, DR 14%, VR 14%). Early termination of pacing because of adverse symptoms was requested by 33% of patients during VR, 19% during DR but only 3% during DM mode. A higher proportion of patients with a fast mode-switching device preferred DM mode (fast 55%, slow 49%), whereas no patients with a fast mode-switching device chose VR as the preferred mode (fast 0%, slow 19%). In the subgroup of patients who had had atrioventricular node ablation, DM was also preferred to VR mode (DM 53%, VR 27%). Overall, there were only two cases of inappropriate mode switching and one case of inappropriate tracking of an atrial tachyarrhythmia. CONCLUSIONS: DM is the pacing mode of choice of patients with paroxysmal atrial tachyarrhythmias. With optimal programming, inappropriate mode switching and tracking of atrial tachyarrhythmias was very uncommon.
No takes yet. Share an insight, caveat, or question.
Kamalvand et al. (1997) conducted an RCT in Paroxysmal atrial tachyarrhythmias and heart block (n=48). DDDR with mode switching (DM) vs. DDDR with conventional upper rate behavior (DR) and VVIR (VR) was evaluated on Exercise time (minutes) (p=<0.01). DDDR pacing with mode switching significantly improved exercise time (8.1 vs 7.0 min, P<0.01) and perceived well-being compared to VVIR pacing, and was the preferred pacing mode in 51% of patients.