Key result
An automated system using recurrence quantification analysis and a Modified EfficientNet-B0 architecture achieved an overall test accuracy of 98.92% for detecting shockable arrhythmias from ECG signals.
Why the study?
Manual cardiac arrhythmia detection has limitations in emergency conditions, creating a pressing need for automated detection of shockable ventricular arrhythmias from ECG signals.
Does an automated system using recurrence quantification analysis and deep convolutional neural networks accurately detect shockable arrhythmias from ECG signals?
Does an automated system using recurrence quantification analysis and deep convolutional neural networks accurately detect shockable arrhythmias from ECG signals?
An automated system using recurrence quantification analysis and deep convolutional neural networks can highly accurately detect shockable arrhythmias from ECG signals without manual feature extraction.
Answers are grounded in this paper and cite their sources.
Automated ECG detection may aid emergency VA identification; leaves open prospective validation before clinical adoption.
Ventricular fibrillation and ventricular tachycardia are shockable cardiac symptoms. These ventricular arrhythmias (VAs) raise the risk of heart failure by causing heart attacks and other heart problems. The electrocardiogram (ECG) is a commonly used and trustworthy technique for identifying cardiac arrhythmia. In case of emergency patient conditions, acknowledging the limitations of manual cardiac arrhythmia detection methods underscores the pressing need for an automated system. This work presents an automated system for the classification of shockable arrhythmia (SA) and nonshockable arrhythmia (NSA) through ECG signals. The proposed work uses recurrence quantification analysis (RQA) to transform 1-D ECG signal into 2-D RQA image. The RQA images are classified into shockable and nonshockable classes on the first stage of classification using modified versions of the last layer of the pretrained AlexNet, DenseNet, ResNet, and EfficientNet. The second stage of classification refines the distinction between SAs [ventricular fibrillation (VF) and ventricular tachycardia (VT)] and NSAs (normal rhythms and other disorders). Experimental validation using the Physionet ECG database demonstrates the effectiveness of our proposed approach. Notably, the Modified EfficientNet-B0 architecture achieves an impressive overall test accuracy of 98.92%. This study contributes to the field by not only providing a robust method for SA detection but also reducing system complexity. The proposed approach eliminates the need for manual feature extraction or beat detection, enhancing its practical applicability in real-world scenarios.
No takes yet. Share an insight, caveat, or question.
Mandal et al. (2024) studied Ventricular fibrillation and ventricular tachycardia (shockable arrhythmias). Automated system using recurrence quantification analysis (RQA) and Modified EfficientNet-B0 was evaluated on Overall test accuracy for classification of shockable and nonshockable arrhythmias. An automated system using recurrence quantification analysis and a Modified EfficientNet-B0 architecture achieved an overall test accuracy of 98.92% for detecting shockable arrhythmias from ECG signals.
Synapse has enriched 10 related papers. Consider them for comparative context: