Key result
The presence of Temperature to time Catch-Up (T2T-Catch-Up) during cryoballoon ablation was strongly associated with durable pulmonary vein isolation, significantly reducing the odds of PV reconnection (OR 0.12).
Why the study?
Procedural endpoints ensuring maximal pulmonary vein isolation durability are important during cryoballoon ablation of paroxysmal AF.
Does the presence of temperature-to-time catch-up (T2T-Catch-Up) during cryoballoon ablation predict durable pulmonary vein isolation in patients with atrial fibrillation?
Observational (n=47)
No
Does the presence of temperature-to-time catch-up (T2T-Catch-Up) during cryoballoon ablation predict durable pulmonary vein isolation in patients with atrial fibrillation?
T2T-Catch-Up is a novel, simple cryoballoon procedural endpoint that strongly predicts durable pulmonary vein isolation and outperforms established parameters like time to isolation.
T2T-Catch-Up was associated with durable PVI; leaves open its role as a procedural marker pending prospective validation.
BACKGROUND: Cryoballoon ablation is a widely used single-shot technique for pulmonary vein isolation (PVI) in the treatment of paroxysmal atrial fibrillation (AF). Procedural endpoints ensuring maximal PVI durability are important. OBJECTIVE: To assess the performance of cryoablation procedural markers to predict long-term PVI. METHODS: In a single center, consecutive patients who underwent redo ablation with high-density mapping for symptomatic AF recurrence after cryoballoon ablation were included and cryoballoon procedural data were collected, including temperature values at 30 and 60 s, time to isolation, nadir temperature and the velocity of temperature decline estimated with the temperature/time catch-up point (T2T-Catch-Up) defined as positive when the freeze temperature in minus degree equals the time in seconds after cryoablation initiation (e.g. - 15 °C in the first 15 s of the ablation impulse). RESULTS: 47 patients (62% male; 58.3 ± 11.2 years) were included. Overall, 38 (80.9%) patients had ≥ 1 reconnected PV. Among 186 PVs, 56 (30.1%; 1.2 per patient on average) were reconnected. Univariate analysis revealed T2T-Catch-Up in 103 (56%) and more frequent in durably isolated than in reconnected PVs (93 [72%] vs 10 [19%], p < 0.0001). Among binary endpoints, T2T-Catch-Up had the highest specificity (82%) and predictive value for durable PVI at redo ablation (90%). In multivariable analyses, absence of T2T-Catch-Up (Odds-ratio 0.12, 95% CI [0.05-0.31], p < 0.0001) and right superior PV (Odds-ratio 3.14, 95% CI [1.27-7.74], p = 0.01) were the only variables independently associated with PV reconnection. CONCLUSION: T2T-Catch-Up, a new and simple cryoballoon procedural endpoint demonstrated excellent predictive value and strong statistical association with durable PVI.
No takes yet. Share an insight, caveat, or question.
Willy et al. (2023) conducted an observational in Paroxysmal atrial fibrillation (n=47). Temperature to time Catch-Up (T2T-Catch-Up) vs. Absence of T2T-Catch-Up was evaluated on Pulmonary vein (PV) reconnection (OR 0.12, 95% CI 0.05-0.31, p=<0.0001). The presence of Temperature to time Catch-Up (T2T-Catch-Up) during cryoballoon ablation was strongly associated with durable pulmonary vein isolation, significantly reducing the odds of PV reconnection (OR 0.12).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:
More on Persistent AF managementMore from Clinical Research in Cardiology