Why the study?
Chordae tendineae cannot be reliably detected in medical imaging due to image quality and artifacts, yet modeling them is essential for simulating the mitral valve in personalized surgery planning systems.
Does a manually refined chordae model improve the approximation of closed mitral valves and reproduction of prolapse compared to a heuristic model in patients scheduled for mitral valve surgery?
Does a manually refined chordae model improve the approximation of closed mitral valves and reproduction of prolapse compared to a heuristic model in patients scheduled for mitral valve surgery?
An interactive editor for refining chordae tendineae models improves the realistic simulation of mitral valve closure and prolapse reproduction for surgical planning.
Answers are grounded in this paper and cite their sources.
May aid mitral valve simulation for surgical planning; leaves open clinical validation before practice change.
PURPOSE: Decision support systems for mitral valve disease are an important step toward personalized surgery planning. A simulation of the mitral valve apparatus is required for decision support. Building a model of the chordae tendineae is an essential component of a mitral valve simulation. Due to image quality and artifacts, the chordae tendineae cannot be reliably detected in medical imaging. METHODS: Using the position-based dynamics framework, we are able to realistically simulate the opening and closing of the mitral valve. Here, we present a heuristic method for building an initial chordae model needed for a successful simulation. In addition to the heuristic, we present an interactive editor to refine the chordae model and to further improve pathology reproduction as well as geometric approximation of the closed valve. RESULTS: For evaluation, five mitral valves were reconstructed based on image sequences of patients scheduled for mitral valve surgery. We evaluated the approximation of the closed valves using either just the heuristic chordae model or a manually refined model. Using the manually refined models, prolapse was correctly reproduced in four of the five cases compared to two of the five cases when using the heuristic. In addition, using the editor improved the approximation in four cases. CONCLUSIONS: Our approach is suitable to create realistically parameterized mitral valve apparatus reconstructions for the simulation of normally and abnormally closing valves in a decision support system.