Why the study?
High-sensitivity cardiac troponin assays allow earlier rule-out of myocardial infarction, but the efficacy and safety of this strategy remained uncertain in suspected acute coronary syndrome.
Does an early rule-out pathway using high-sensitivity cardiac troponin I <5 ng/L at presentation reduce length of stay without increasing 30-day myocardial infarction or cardiac death in patients with suspected acute coronary syndrome?
Does an early rule-out pathway using high-sensitivity cardiac troponin I <5 ng/L at presentation reduce length of stay without increasing 30-day myocardial infarction or cardiac death in patients with suspected acute coronary syndrome?
Answers are grounded in this paper and cite their sources.
An early rule-out pathway for suspected ACS using high-sensitivity troponin I <5 ng/L at presentation significantly reduced length of stay and increased discharges without increasing cardiac events at 1 year.
Objectives High-sensitivity cardiac troponin assays enable myocardial infarction to be ruled out earlier, but the efficacy and safety of this approach is uncertain. We investigated whether an early-rule out pathway is safe and effective for the management of patients with suspected acute coronary syndrome. Design A stepped-wedge cluster randomised controlled trial. Setting Seven acute care hospitals in Scotland. Participants 31,492 consecutive patients with suspected acute coronary syndrome between December 2014 to December 2016. Intervention Sites were randomised to implement an early rule-out pathway where myocardial infarction was ruled out if high-sensitivity cardiac troponin I concentrations were <5 ng/L at presentation. During a prior validation phase, myocardial infarction was ruled out where troponin concentrations were < 99 th centile at 6-12 hours after symptom onset. Main outcome measures The co-primary outcome was length of stay (efficacy), and myocardial infarction or cardiac death after discharge at 30 days (safety). Patients were followed for 1 year to evaluate the safety outcome and other secondary outcomes. Results We enrolled 31,492 patients (59±17 years, 45% women) with troponin concentrations < 99 th centile at presentation. The length of stay was reduced from 10.1±4.1 to 6.8±3.9 hours (adjusted geometric mean ratio 0.78, 95% confidence interval [CI] 0.73 to 0.83, P< 0.001) following implementation, and the proportion of patients discharged increased from 50% to 71% (adjusted odds ratio [aOR] 1.59, 95% CI 1.45 to 1.75). Non-inferiority was not demonstrated for the 30-day safety outcome (upper limit of one-sided 95% CI for adjusted risk difference 0.70%, non-inferiority margin 0.50%, P = 0.068), but the observed differences favoured the early rule-out pathway (0.4% [57/14,700] versus 0.3% [56/16,792]). At 1 year, the safety outcome occurred in 2.7% (396/14,700) and 1.8% (307/16,792) of patients before and after implementation (aOR 1.02, 95% CI 0.74 to 1.40, P = 0.894), and there were no differences in hospital reattendance or all-cause mortality. Conclusions Implementation of an early rule-out pathway for myocardial infarction reduced length of stay and hospital admission. Whilst non-inferiority for the safety outcome was not demonstrated at 30 days, there was no increase in cardiac events at 1 year. Adoption of this pathway will have major benefits for patients and healthcare providers. Trial registration http://ClinicalTrials.gov number, NCT03005158
No takes yet. Share an insight, caveat, or question.
Anand et al. (2020) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: