Why the study?
While baseline high-sensitivity cardiac troponin concentrations can identify patients at high risk for acute MI, the relationship between baseline concentrations and positive predictive values for acute MI required evaluation.
What is the positive predictive value of baseline high-sensitivity cardiac troponin I concentrations for acute myocardial infarction in emergency department patients?
What is the positive predictive value of baseline high-sensitivity cardiac troponin I concentrations for acute myocardial infarction in emergency department patients?
Answers are grounded in this paper and cite their sources.
A single baseline hs-cTnI measurement >200 ng/L identifies emergency department patients at high risk for acute MI, though serial testing remains important for definitive diagnosis.
To the Editor: Baseline high-sensitivity (hs) cardiac troponin (cTn) assay concentrations are used to allow for safe, rapid acute myocardial infarction (MI) rule-out at presentation (1,). Baseline concentrations can also identify patients at high risk for acute MI (2). We evaluated the relationship between baseline hs-cTnI concentrations and positive predictive values (PPV) for acute MI in emergency department (ED) patients undergoing cTn testing. Following institutional review board approval, we studied a prospective cohort of unselected patients presenting to our ED in whom serial cTnI measurements were obtained on clinical indication (Use of TROPonin I in Acute coronary syndromes, UTROPIA, NCT02060760). Study methods and results have been reported (3, 4). Fresh EDTA plasma samples were simultaneously measured with contemporary cTnI (clinically used) and hs-cTnI (investigational) assays (Abbott ARCHITECT i1000SR or i2000SR analyzers). Sex-specific hs-cTnI 99th percentile upper reference limits (URL) were 16 ng/L, women, and 34 ng/L, men. Cases with at least one hs-cTnI >99th percentile URL were adjudicated using hs-cTnI according to the Third Universal Definition of MI. The present is a secondary analysis evaluating the relationship of baseline hs-cTnI and PPVs for acute MI during the index hospitalization. Among 1631 patients, 415 (25%) had at least one hs-cTnI concentration above sex-specific 99th percentile URLs. Acute MI occurred in 170 (10.4%), including 68 (4.2%) type 1 MI (T1MI), and 102 (6.3%) type 2 MI (T2MI). Median time from ED presentation to first blood draw was 0.8 hours. Using baseline hs-cTnI, sex-specific 99th percentile URLs resulted in the following PPVs: acute MI, 37% (95% confidence interval (CI): 32, 43); T1MI, 20% (CI: 15, 25); and T2MI, 26% (CI: 20, 31). Higher baseline hs-cTnI concentrations were associated with higher PPVs for acute MI and T1MI, but not T2MI (Fig. 1). Median (interquartile range) baseline hs-cTnI concentrations were 36 ng/L (15, 75) for T2MI, 79 ng/L (21, 499) for T1MI, and 28 ng/L (21, 68) for myocardial injury. At higher concentrations, fewer patients with acute MI were identified. Baseline hs-cTnI concentrations of >200 ng/L gave a PPV of 70% (CI: 57, 83) for acute MI. Baseline hs-cTnI concentrations of >600 ng/L corresponded to a PPV of 68% (CI: 48, 88) for T1MI. Relationship between baseline hs-cTnI (ng/L) concentration and PPV (95% confidence intervals) for acute MI, including type 1 and 2 MIs and percentage of MIs identified. Our study offers several unique observations. First, while the 99th percentile URL is the preferred diagnostic threshold for the diagnosis of acute MI, we show that an isolated baseline increase above the 99th percentile URL has a poor PPV for acute MI. For diagnostic purposes, these findings underscore the importance of evaluating serial results in the context of the patient’s clinical presentation rather than a single sample >99th percentile URL. Second, for risk-stratification, baseline cTn concentration thresholds can be tailored to target either a very high negative predictive value to identify patients at low risk for acute MI, or to a high PPV, to identify patients at higher risk for acute MI in whom hospital admission and cardiac evaluation may be warranted. Using the Abbott hs-cTnI assay, we and others have demonstrated that very low hs-cTn concentrations that are either undetectable or <5 ng/L (optimized threshold) identify patients at low risk (1, 4,). The present analysis demonstrates that a baseline hs-cTnI >200 ng/L identifies a subset of patients at high risk for acute MI, due to the relationship between PPVs and T1MIs. This threshold is approximately 4-fold higher than the 52 ng/L rule-in threshold endorsed by the European Society of Cardiology (5); likely because of differences in the populations studied. To optimize PPVs for T1MI, much higher concentrations (>600 ng/L) are needed, with analyses limited by small sample size. Third, we demonstrate a paradoxical, inverse relationship between higher baseline hs-cTnI concentrations and PPVs for T2MI, which likely occurs because many patients with myocardial injury also have similar or higher baseline concentrations. Limitations exist. First, PPVs are influenced by disease prevalence, and risk-stratification thresholds aimed at identifying high-risk patients may vary according to the pretest probability of the examined population. Our analyses are based on an all-comers population that evaluates the test as used in real-world US clinical practice, and may differ if restricted to chest discomfort cohorts as more commonly studied outside the US. Second, our small MI sample size limits analyses. Third, no consensus exists on what constitutes high risk, with most analyses aimed at identifying patients at high risk targeting a PPV of at least 70%. Fourth, clinicians did not have access to the investigational hs-cTnI results. In conclusion, baseline hs-cTnI concentration thresholds can be optimized to target desired PPVs and facilitate the more rapid identification of patients at higher risk for acute MI, particularly T1MI. All authors confirmed they have contributed to the intellectual content of this paper and have met the following 4 requirements: (a) significant contributions to the conception and design, acquisition of data, or analysis and interpretation of data; (b) drafting or revising the article for intellectual content; (c) final approval of the published article; and (d) agreement to be accountable for all aspects of the article thus ensuring that questions related to the accuracy or integrity of any part of the article are appropriately investigated and resolved. Upon manuscript submission, all authors completed the author disclosure form. Disclosures and/or potential conflicts of interest: F.S. Apple, Clinical Chemistry, AACC. Y. Sandoval, advisory boards for Abbott Diagnostics and Roche Diagnostics without personal financial compensation, speaker for Abbott Diagnostics without personal financial compensation; F.S. Apple, LumiraDx, HyTest. None declared. S.W. Smith, Abbott Diagnostics; F.S. Apple, Siemens Healthineers, Abbott Diagnostics. F.S. Apple, Abbott Diagnostics, nonsalaried through research institute. None declared. None declared.
No takes yet. Share an insight, caveat, or question.
Sandoval et al. (2020) studied this question.