Key result
A patient-specific approach using constructed wavelets detected 32 out of 34 epileptic seizures with five false detections in 10 patients, performing better than the Daubechies wavelet.
Why the study?
Does a patient-specific wavelet construction approach improve automatic detection of epileptic seizures in EEG signals compared to standard wavelets?
Does a patient-specific wavelet construction approach improve automatic detection of epileptic seizures in EEG signals compared to standard wavelets?
A patient-specific wavelet construction method based on EEG data shows promise for accurate, real-time automatic detection of epileptic seizures.
May aid patient-specific EEG seizure detection; leaves open prospective validation before clinical adoption.
Epileptic seizures are caused by excessive, synchronized activity of large groups of neurons. In human electroencephalograph (EEG), they are reflected by multiple epileptic characteristic waves. Based on the idea of template matching, this paper presents a patient-specific approach for the automatic detection of epileptic seizures. In our method, a set of wavelets are constructed based on the epileptic characteristic waves extracted from training EEG signals, and then continuous wavelet transform (CWT) is performed on the recorded EEG. The coefficients of CWT reflect the similarity of the recorded EEG and the epileptic characteristic waveforms and thus can be used to detect if the epileptic characteristic waveforms exist in the EEG. After applying data fusion to the CWT coefficient matrices corresponding to the multiple constructed wavelets, the boundaries of seizures can be determined. In the experiment, our constructed wavelets performed better in the detection of epileptic characteristic waves compared to the Daubechies wavelet. We analyzed the EEG of 10 patients and our method detected 32 out of 34 seizures and declared five false detections. Therefore, our method is promising for the automatic detection of epileptic seizures and the real-time monitoring of patients' EEG signal.
No takes yet. Share an insight, caveat, or question.
Gu et al. (2018) studied Epileptic seizures (n=10). Patient-specific approach using constructed wavelets and continuous wavelet transform vs. Daubechies wavelet was evaluated on Detection of epileptic seizures. A patient-specific approach using constructed wavelets detected 32 out of 34 epileptic seizures with five false detections in 10 patients, performing better than the Daubechies wavelet.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: