Key result
Automated dual-sequence CMR perfusion mapping correlates strongly with 13N-NH3 PET for myocardial perfusion quantification.
Observational (n=21)
Answers are grounded in this paper and cite their sources.
BACKGROUND: Recent studies have shown that quantification of myocardial perfusion (MP) at stress and myocardial perfusion reserve (MPR) offer additional diagnostic and prognostic information compared to qualitative and semi-quantitative assessment of myocardial perfusion distribution in patients with coronary artery disease (CAD). Technical advancements have enabled fully automatic quantification of MP using cardiovascular magnetic resonance (CMR) to be performed in-line in a clinical workflow. The aim of this study was to validate the use of the automated CMR perfusion mapping technique for quantification of MP using 13N-NH3 cardiac positron emission tomography (PET) as the reference method. METHODS: Twenty-one patients with stable CAD were included in the study. All patients underwent adenosine stress and rest perfusion imaging with 13N-NH3 PET and a dual sequence, single contrast bolus CMR on the same day. Global and regional MP were quantified both at stress and rest using PET and CMR. RESULTS: There was good agreement between global MP quantified by PET and CMR both at stress (-0.1 ± 0.5 ml/min/g) and at rest (0 ± 0.2 ml/min/g) with a strong correlation (r = 0.92, p < 0.001; y = 0.94× + 0.14). Furthermore, there was strong correlation between CMR and PET with regards to regional MP (r = 0.83, p < 0.001; y = 0.87× + 0.26) with a good agreement (-0.1 ± 0.6 ml/min/g). There was also a significant correlation between CMR and PET with regard to global and regional MPR (r = 0.69, p = 0.001 and r = 0.57, p < 0.001, respectively). CONCLUSIONS: There is good agreement between MP quantified by 13N-NH3 PET and dual sequence, single contrast bolus CMR in patients with stable CAD. Thus, CMR is viable in clinical practice for quantification of MP.
No takes yet. Share an insight, caveat, or question.
Engblom et al. (2016) conducted an observational in Stable coronary artery disease (n=21). Automated dual sequence, single contrast bolus CMR perfusion mapping vs. 13N-NH3 cardiac positron emission tomography (PET) was evaluated on Global and regional myocardial perfusion (MP) and myocardial perfusion reserve (MPR) agreement and correlation between CMR and PET (r = 0.92 (global MP), r = 0.83 (regional MP), p=<0.001). Automated dual-sequence CMR perfusion mapping showed strong correlation and good agreement with 13N-NH3 PET for global and regional myocardial perfusion.
Synapse has enriched 10 related papers. Consider them for comparative context: