BACKGROUND: Continuous glucose monitoring (CGM) users are encouraged to consider trend arrows before injecting a meal bolus. We evaluated the efficacy and safety of two different algorithms for trend-informed bolus adjustments, the Diabetes Research in Children Network/Juvenile Diabetes Research Foundation (DirectNet/JDRF) and the Ziegler algorithm, in type 1 diabetes. METHODS: We conducted a cross-over study of type 1 diabetes patients using Dexcom G6. Participants were randomly assigned to either the DirectNet/JDRF or the Ziegler algorithm for two weeks. After a 7-day wash-out period with no trend-informed bolus adjustments, they crossed to the alternative algorithm. RESULTS: Twenty patients, with an average age of 36 ± 10 years, completed this study. Compared to the baseline and the DirectNet/JDRF algorithm, the Ziegler algorithm was associated with a significantly higher time in range (TIR) and lower time above range and mean glucose. A separate analysis of patients on CSII and MDI revealed that the Ziegler algorithm provides better glucose control and variability than DirectNet/JDRF in CSII-treated patients. The two algorithms were equally effective in increasing TIR in MDI-treated patients. No severe hypoglycemic or hyperglycemic episode occurred during the study. CONCLUSIONS: The Ziegler algorithm is safe and may provide better glucose control and variability than the DirectNet/JDRF over a two-week period, especially in patients treated with CSII.