Answers are grounded in this paper and cite their sources.
This paper provides a full study of a photovoltaic (PV)-aided plug-in hybrid electric vehicle (PHEV) charging facility by investigating the two most challenging technical issues: 1) sizing of the local energy storage (LES) unit and 2) control strategies of the facility. First, the paper proposes a method for determining the optimal size of LES for a charging facility. Second, the paper develops a control strategy for the integration of the PHEV charging stations with the proposed LES and PVs. The proposed LES-sizing method, which is based on optimal control theory, minimizes a cost function based on the average value of kilowatt-hour price, irradiance, and PHEVs' usage patterns. A power-loss/temperature-based battery model and a temperature-based charging strategy previously developed by the authors are utilized to determine the optimal LES size. Afterward, with the optimized facility parameters, a detailed circuit model of the charging facility, including PVs, PHEVs, and LES, is constructed with a real-time simulation system. While an experimental setup for this kind of complex and high-cost system was not readily feasible, real-time simulation was carried out to prove the effectiveness of the proposed control strategy. To validate the effectiveness and accuracy of the real-time simulation, control hardware-in-the-loop (HIL) and power-inverter-based experiments have been carried out at the subsystem level.
No takes yet. Share an insight, caveat, or question.
Guo et al. (2012) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: