Key result
Pulsed field ablation reduces 6-month heart rate increase by ~4 bpm versus thermal ablation.
Its licence doesn't allow us to show a copy here.
Why the study?
Thermal ablation of AF causes autonomic denervation that may impact outcomes, but the relative myocardial selectivity of pulsed field ablation may minimize autonomic effects.
Does pulsed field ablation attenuate autonomic effects compared to thermal ablation in patients with paroxysmal atrial fibrillation?
RCT (n=379)
randomized
Does pulsed field ablation attenuate autonomic effects compared to thermal ablation in patients with paroxysmal atrial fibrillation?
Absolute Event Rate: 5.9% vs 10.1%
p-value: p=0.02
Pulsed field ablation for paroxysmal AF results in less autonomic denervation compared to thermal ablation, as measured by heart rate and heart rate variability.
BACKGROUND Autonomic denervation is an ancillary phenomenon during thermal ablation of atrial fibrillation (AF), that may have synergistic effects on symptomatic improvement and long-term freedom from AF. Pulsed field ablation (PFA), a non-thermal ablation modality, was non-inferior to thermal ablation in treating AF; however, PFA's relative myocardial selectivity may minimize autonomic effects. OBJECTIVES Compare heart rate (HR) and heart rate variability (HRV) metrics as markers of autonomic function after ablation using PFA versus thermal ablation. METHODS ADVENT was a randomized pivotal study comparing PFA (pentaspline catheter) with thermal ablation (radiofrequency [RF] or cryoballoon [CB]) for treating paroxysmal AF. Baseline HR was acquired from a pre-ablation 12-lead ECG, while follow-up HRs, as well as HRV (SDNN, SDANN) metrics, were derived from 72-hour Holter monitors at 6 and 12-months. RESULTS This study included 379 paroxysmal AF patients undergoing PFA (n=194) or thermal ablation (n=185; n=102 RF, n=83 CB) completing 6 and 12-month Holter monitors. Compared to PFA, thermal patients had significantly greater increases in HR from baseline to 6 months (ΔHR; 10.1 vs. 5.9bpm; p=0.02) and 12 months (ΔHR; 8.8 vs. 5.2bpm; p=0.03). This increase in HR at 6 and 12 months was similar between CB and RF (p=0.94 and 0.83, respectively). HRV, both SDNN and SDANN, were significantly lower at both 6- and 12-month after thermal ablation compared to PFA (p<0.01). CONCLUSIONS PFA's effect on the autonomic nervous system was attenuated compared to thermal ablation. Whether this affects long-term freedom from AF or symptomatic bradycardia/pauses after AF ablation requires further study.
No takes yet. Share an insight, caveat, or question.
Gerstenfeld et al. (2024) conducted an RCT in paroxysmal atrial fibrillation (n=379). Pulsed field ablation vs. Thermal ablation (radiofrequency or cryoballoon) was evaluated on Change in heart rate from baseline to 6 months (p=0.02). Pulsed field ablation resulted in a significantly smaller increase in heart rate at 6 months compared to thermal ablation (5.9 vs 10.1 bpm; p=0.02).