Given the critical role of electrical cabinets in the post-earthquake recovery and emergency response of nuclear power plants (NPPs), a comprehensive assessment of their seismic performance is essential to ensure operational safety. This study analyzed seismic behavior by fabricating an electrical cabinet model based on the dynamic characteristics and field surveys of equipment installed in a Korean-type NPP. A shaking table test with simultaneous tri-axial excitation was conducted, incrementally increasing the seismic motion until damage was observed. A numerical model was then developed based on the experimental results, followed by a seismic response analysis and comparison of results. The findings verified that assuming fixed anchorage conditions in the numerical model may significantly overestimate seismic performance, as it fails to account for the nonlinear behavior of the anchorage system, as well as the superposition between global and local modes caused by cabinet rocking and impact under strong seismic loading. Furthermore, damage and impact at the anchorage amplified acceleration responses, significantly affecting the high-frequency range and the vertical behavior, leading to substantial amplification of the in-cabinet response spectrum.
No takes yet. Share an insight, caveat, or question.
Yun et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: