Answers are grounded in this paper and cite their sources.
Angiogenesis, the process of new blood vessel formation from pre-existing vasculature, is central to both normal physiological and pathological processes, including embryonic development, wound healing, cancer, and cardiovascular diseases.1 Accurate quantification of angiogenesis, both in vitro and in vivo tissue sections, is critical for understanding its mechanisms and guiding therapeutic development. Despite widespread use of imaging methods, such as fluorescence microscopy and phase-contrast imaging, analyzing vascular structures remains challenging. Existing software tools are often modality specific, require coding expertise, or are outdated. Many are sensitive to noise or uneven lighting, require long processing times, or only offer limited throughput. While deep learning methods offer powerful automation, their requirement for large, consistently annotated training datasets can be a barrier. For example, the AngioCells dataset,2 one of the few public in vitro datasets, contains just 275 images, which are insufficient to train robust deep learning models across varied imaging conditions. To comprehensively assess the current landscape of angiogenesis analysis tools, we conducted a systematic review of the PubMed database using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA).3 Our PubMed search query (see the GitHub repository for the full query) yielded 437 studies; after screening and exclusions (Figure 1A), we identified seven relevant studies. Of these, four provide usable software: Angiogenesis Analyzer,4 REAVER,5 Vessel Metrics,6 and AutoTube.7 Limitations across these tools include (i) license restrictions (REAVER and AutoTube); (ii) significant setup effort, including the installation of dependencies and libraries (Vessel Metrics); and (iii) slow or artifact-sensitive performance (Angiogenesis Analyzer). Development and validation of the NEREA computer vision platform for angiogenesis image analysis. (A) PRISMA diagram from the systematic review. (B) Overview of NEREA’s interface and output. (Bi) The GUI displays loaded images, processed status, and previews. (Bii) Histograms showing branch length distribution with normality testing. (C) (Ci) Automated image analysis pipeline. (Cii) Image overlays and segmentation mask comparisons across the manual gold standard, Angiogenesis Analyzer, and NEREA from the AngioCells dataset (Ciii) Segmentation comparisons across manual, REAVER, and NEREA masks in retina, liver, and heart images from the REAVER dataset. (D) Validation of NEREA in the AngioCells dataset. (Dii-iv) Metric comparison (n = 275); (Eiv-ix) The Bland–Altman analysis of agreement with manual quantification for both Angiogenesis Analyzer (Dv-vii) and NEREA (Dviii-x). Panels show (from top to bottom) number of branches, total branch length, and number of branch points. Data points represent individual images (n = 275). Dashed lines indicate mean bias; colored portion shows 95% limits of agreement. ICC values are displayed for each comparison. (Di) Processing time comparison. (E) Validation of NEREA in the REAVER dataset. (Ei-vi) Quantitative comparison across software vs. manual (n = 36). Statistical tests: RM ANOVA (parametric), Friedman ANOVA (nonparametric). (Evii-ix) Segmentation metrics: specificity, precision, and sensitivity. Statistical tests: Friedman ANOVA (F) Application of NEREA to disease models. Representative skeleton overlay of (i) control and (ii) PAH iPSC-ECs. Quantification of (iii) total branch length, (iv) number of branches, and (v) branch points for control (n = 2 biological lines, two technical replicates each) vs. PAH (n = 3 biological lines, two technical replicates each); Welch’s t-test. Data points represent the mean of technical replicates for each biological line. Representative skeleton overlay of (vi) control and (vii) HGPS iPSC-ECs. (viii-x) Quantification for control (n = 2 biological lines, 11 technical replicates) vs. HGPS (n = 2 biological lines, 14 technical replicates); nested t-test. Data are mean ± SEM. *P < 0.05; **P < 0.01; ***P < 0.001; ****P < 0.0001. To address these limitations in the field, we developed NEREA (Next-gen Engine for Rapid and Efficient Angiogenesis Analysis). This robust, classical computer vision-based software provides a robust, rules-based alternative that performs consistently without the need for model training. Its pipeline enables accurate analysis of diverse image types (e.g. phase-contrast and fluorescent). Following user-defined parameter initialization, NEREA performs rapid, unattended batch processing. A key innovation is its intelligent masking feature that automatically excludes imaging artifacts, such as plate borders, a common failure point for other tools. NEREA is a free, standalone, multiplatform application (Windows, macOS, Linux) with an intuitive graphical user interface (GUI) (Figure 1. Bi). Its processing pipeline (Figure 1. Ci) includes optional preprocessing (inversion, noise reduction, CLAHE contrast enhancement, and background subtraction), segmentation using Otsu thresholding, and Canny edge detection, among others, followed by gap closure, smoothing, intelligent masking (optional), and skeletonization via PlantCV.8 The quantitative metrics generated via NEREA include branch counts, lengths, branching points, stem/tip distinction, total vessel length, diameter, area, and execution time. Additionally, individual branch lengths are tested for normality and represented in a histogram (Figure 1. Bii). Pixel-based data can then be converted to micrometres with user-defined calibration. We validated NEREA using two publicly available datasets, REAVER5 and AngioCells,2 using manual quantification as the gold standard. On the in vivo REAVER dataset, a vascular network dataset (Figure 1. Ciii), NEREA was compared against four other tools (AutoTube,7 Vessel Metrics,6 REAVER,5 and Angiogenesis Analyzer4) using the most optimized settings to reflect real-world usability (see Supplementary material online, Tables S1 and S2). The Bland–Altman analysis revealed the expected variability inherent in vascular network quantification, with all tools showing substantial 95% limits of agreement relative to manual annotation (see Supplementary material online, Table S3). Despite this, NEREA demonstrated competitive agreement, showing the smallest mean bias for mean diameter (0.62 pixels) and substantially lower bias for branch count (5.86) compared to REAVER (31.97), Angiogenesis Analyzer (31.39), and Vessel Metrics (94.14). We quantified the following as parameters (where applicable): (i) mean vessel diameter, (ii) number of branching points, (iii) mean vessel length, (iv) occupied vessel area, (v) number of branches, and (vi) processing time per image (Figure 1. Ei-vi). Intraclass correlation coefficient (ICC) analysis demonstrated that NEREA achieved excellent reliability across all metrics (ICC > 0.93), matching or exceeding the performance of existing tools (see Supplementary material online, Table S4). Specifically, NEREA showed the highest ICC values for vessel area (0.93), mean diameter (0.95), branch points (0.96), and branch count (0.95). For vessel length, NEREA showed equal reliability to AutoTube (ICC = 0.94 for both), but with tighter limits of agreement in the Bland–Altman analysis, NEREA showed comparable performance to other tools in several key metrics, particularly mean vessel diameter and branch count (Friedman test, no significant difference vs. manual, P > 0.99), and matched REAVER for vessel area and branching points. Multiple tools demonstrated excellent reliability for vessel length quantification, with NEREA performing competitively alongside REAVER and AutoTube (all ICC > 0.93). However, NEREA’s processing time was faster than both Angiogenesis Analyzer and Vessel Metrics (P < 0.0001) and comparable to REAVER and AutoTube. Additional segmentation performance metrics (specificity, sensitivity, and precision)9 were equivalent to REAVER (Figure 1. Evii-ix) (Friedman test, no significant difference vs. REAVER, P > 0.99). These results confirm NEREA’s high accuracy and efficiency in quantifying vascular structures from in vivo images. For the in vitro AngioCells dataset (Figure 1. Cii), which includes variable-quality phase-contrast images, only NEREA and Angiogenesis Analyzer could analyse the images (Figure 1. Dii-iiv). The Bland–Altman and ICC analyses provided a comprehensive assessment of agreement with manual quantification (see Supplementary material online, Tables S5–S6). While both tools showed systematic overestimation of total branch length with similar reliability (ICC = 0.74 vs. 0.77), NEREA demonstrated superior performance for network complexity metrics. NEREA showed substantially smaller biases for branch count (84.4 vs. 311.7) and branch points (67.2 vs. 168.6), with correspondingly higher ICC values (0.71–0.72 vs. 0.58–0.59), indicating better reliability (Figure 1. Dv-x). These results demonstrate that NEREA provides more accurate and reliable quantification of in vitro angiogenesis network complexity. NEREA’s processing time was ∼20× faster than Angiogenesis Analyzer (38 min vs. > 12 h, P < 0.0001) (Figure 1. Di), making it more suitable for high-throughput processing. To demonstrate NEREA’s utility in cardiovascular disease research, we applied it as a proof of concept to analyse tube formation in human-induced pluripotent stem cell-derived endothelial cells (iPSC-ECs) from two vascular diseases well-known for their pronounced EC dysfunction: BMPR2 deficiency pulmonary arterial hypertension (PAH) lines and patient-derived LMNA mutation Hutchinson–Gilford progeria syndrome (HGPS) lines (Figure 1. F). A key advantage of NEREA was immediately apparent; while the Angiogenesis Analyzer erroneously detected the circular image border as part of the vascular network, NEREA’s intelligent masking step correctly excluded it, ensuring accurate segmentation. NEREA robustly quantified significant morphological deficits consistent with the known angiogenic impairment in these models. In the PAH ECs (Figure 1. Fi-ii), we observed a significant reduction in total branch length (Welch’s t-test, P = 0.0494; Figure 1. Fiii), number of branches (P = 0.022; Figure 1. Fiv), and branch points (P = 0.0292; Figure 1. Fv). Similarly, in the HGPS ECs (Figure 1. Fvi-vii), NEREA detected a significant decrease in total branch length (nested t-test, P = 0.0356; Figure 1. Fviii), number of branches (P = 0.0279; Figure 1. Fix), and branch points (P = 0.0195; Figure 1. Fx). These proof-of-concept results demonstrate NEREA’s utility for disease modeling applications that require high-throughput, artifact-resistant analysis. Future studies with larger patient cohorts can leverage NEREA’s capabilities for more comprehensive investigations. NEREA addresses longstanding barriers in angiogenesis analysis software: it is free, fast, easy to use, and versatile. Unlike deep learning tools, it does not require training datasets, and its performance is consistent across imaging conditions. Furthermore, by providing rapid, accurate analysis, tools such as NEREA can help generate the high-quality annotated datasets needed to train robust deep learning models in the future. While highly effective, NEREA’s performance on noisy or extremely low-contrast images may require further parameter optimization. Planned improvements for NEREA include machine learning–based robustness enhancements, automatic parameter tuning, and parallelization to further improve processing speed. In summary, NEREA (i) directly addresses identified gaps in classical computer vision-based angiogenesis analysis (cost, speed, accessibility, robustness) based on a PRISMA systematic review; (ii) uses a unique intelligent artifact masking algorithm that automatically excludes imaging artifacts, such as plate borders, a common failure point for other angiogenesis analysis tools; (iii) uniquely combines speed, accuracy, artifact resistance, and user-friendliness in a single free package; (iv) is a versatile tool validated to perform robustly across both in vivo (fluorescence/confocal) and in vitro (phase-contrast) images without requiring modality-specific training in a reasonable run time for high-throughput processing; and (v) provides normality testing and histograms for branch length distributions. NEREA’s ability to quantify disease-specific phenotypes in iPSC-EC models makes it a promising tool for cardiovascular research. By overcoming the limitations of existing methods, NEREA sets a new standard for angiogenesis quantification. Supplementary material is available at Cardiovascular Research online. We thank Drs Zehra Yildirim and Mao Zhang for testing the software. We thank Blake Wu for assistance with manuscript proof-reading. The HGPS lines and controls were obtained from the Progeria Research Foundation. This project was funded in part by the American Heart Association U54HL120163 and 23DIVSUP1076489, University of California Office of the President (UCOP)Tobacco-Related Disease Research Project T34FT8070 (to N.J-T.), and National Institutes of Health (NIH) R01 HL130020, R01 HL146690, R01 HL176822, U01 AI195484, and UM1 TR006031 (to J.C.W.). NEREA is freely available for academic and non-commercial research use under the condition that any work (publications, presentations, or software) using this tool must cite this paper. Access the software and wiki on GitHub: https://github.com/nereajt/NEREA/wiki.
No takes yet. Share an insight, caveat, or question.
Jiménez-Téllez et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: