Subminiature hot-wire sensors have been developed and qualified to measure small-scale turbulent motions. Measurements were made with hot wires having 0.625, 1.25 and 5 mu m nominal diameters and lengths ranging from 50 mu m to 3 mm. The smallest sensor has a spatial resolution about ten times better than typical commercially available probes. The measurements were made in the inner layer of a turbulent boundary layer near a smooth wall where the viscous length scale v/U r was about 50 mu m. The data show how measurement of time-averaged longitudinal turbulence intensity is dependent on sensor dimensions.
No takes yet. Share an insight, caveat, or question.
Ligrani et al. (1987) studied this question.