Key result
Lactate threshold markers showed strong correlations (r=0.81-0.98) with critical power, but wide limits of agreement (up to ±52 W) suggest caution when using them interchangeably.
Why the study?
The study was conducted to analyze the relationship between critical power and different lactate threshold markers in cyclists.
Cross-Sectional (n=17)
No
Effect estimate: r = 0.81-0.98
p-value: p=<0.001
Lactate threshold markers show strong association with critical power in recreational cyclists, but wide limits of agreement suggest they should not be used interchangeably.
May inform CP estimation via LT2 in recreational cyclists; leaves open optimal marker alignment.
Purpose: To analyze the relationship between critical power (CP) and different lactate threshold (LT2) markers in cyclists. Methods: Seventeen male recreational cyclists [33 ± 5 years, peak power output (PO) = 4.5 ± 0.7 W/kg] were included in the study. The PO associated with four different fixed (onset of blood lactate accumulation) and individualized (Dmax exp , Dmax pol , and LT Δ1 ) LT2 markers was determined during a maximal incremental cycling test, and CP was calculated from three trials of 1-, 5-, and 20-min duration. The relationship and agreement between each LT2 marker and CP were then analyzed. Results: Strong correlations ( r = 0.81–0.98 for all markers) and trivial-to-small non-significant differences (Hedges’ g = 0.01–0.17, bias = 1–9 W, and p > 0.05) were found between all LT2 markers and CP with the exception of Dmax exp , which showed the strongest correlation but was slightly higher than the CP (Hedges’ g = 0.43, bias = 20 W, and p < 0.001). Wide limits of agreement (LoA) were, however, found for all LT2 markers compared with CP (from ±22 W for Dmax exp to ±52 W for Dmax pol ), and unclear to most likely practically meaningful differences (PO differences between markers >1%, albeit <5%) were found between markers attending to magnitude-based inferences. Conclusion: LT2 markers show a strong association and overall trivial-to-small differences with CP. Nevertheless, given the wide LoA and the likelihood of potentially meaningful differences between these endurance-related markers, caution should be employed when using them interchangeably.
No takes yet. Share an insight, caveat, or question.
Valenzuela et al. (2021) conducted a cross-sectional in Healthy recreational cyclists (n=17). Lactate threshold markers (Dmaxexp, Dmaxpol, OBLA, LTΔ1) vs. Critical Power (CP) was evaluated on Correlation and agreement between lactate threshold markers and critical power (r = 0.81-0.98, p=<0.001). Lactate threshold markers showed strong correlations (r=0.81-0.98) with critical power, but wide limits of agreement (up to ±52 W) suggest caution when using them interchangeably.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: