Why the study?
Diagnosis of metabolic syndrome and cardiovascular disorders can benefit from physical activity and energy expenditure assessment, motivating investigation into the relationship between MET scores and seismocardiogram-derived parameters.
Seismocardiogram components, particularly the lateral axis and 0-20 Hz band, can accurately classify physical activity types and estimate energy expenditure, which may aid in monitoring metabolic syndrome and cardiovascular disorders.
Answers are grounded in this paper and cite their sources.
SCG-MET associations may support wearable monitoring; leaves open clinical validation in cardiovascular populations.
OBJECTIVE: The diagnosis of metabolic syndrome and cardiovascular disorders can highly benefit from physical activity and energy expenditure assessment. In this study, we investigated the relationship between metabolic equivalent of task (MET) scores and seismocardiogram (SCG)-derived parameters. METHODS: We worked with the PAMAP2 dataset and focused on the 3-axial chest acceleration data. We first segmented the 3-axial SCG signals into respiration (0-1 Hz), cardiac vibrations (1-20 Hz) and heart sounds (20-40 Hz) components. Additionally, we investigated their combinations: 0-20 Hz, 1-40 Hz and 0-40 Hz. We then windowed each signal, and extracted time and frequency domain features from each window. Using the MET scores and activity types, we trained linear regression and random forest classification models first using 80-20% split, then with leave-one-subject-out cross-validation (LOSO-CV). Additionally, we investigated the significance of each feature and axis. RESULTS: For the 80-20% task, the best performing frequency bands were 0-1 Hz, 0-20 Hz, and 0-40 Hz, which yielded a (MET mean-squared-error, classification accuracy) pair of (0.354, 0.952), (0.367, 0.904), and (0.377, 0.914), respectively. When LOSO-CV was applied, we obtained (1.059, 0.865), (0.681, 0.868), and (0.804, 0.875) for each band, respectively. Additionally, our results revealed that the lateral axis provides the most critical information about cardiorespiratory effect of performed activities. CONCLUSION: Different SCG components can provide unique and substantial contributions to activity and energy expenditure assessment. SIGNIFICANCE: This framework can be leveraged in the design of wearable systems for monitoring the activity and energy expenditure levels, and understanding their relationship with underlying cardiorespiratory parameters.
No takes yet. Share an insight, caveat, or question.
Tokmak et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: