Why the study?
Breath-holding duration during CMR poses a key challenge that is difficult for cardiac patients.
Does artificial intelligence-assisted compressed sensing CINE reduce image acquisition time and preserve image quality compared to conventional CINE in cardio-oncology patients and healthy volunteers?
Does artificial intelligence-assisted compressed sensing CINE reduce image acquisition time and preserve image quality compared to conventional CINE in cardio-oncology patients and healthy volunteers?
AI-assisted compressed sensing CINE significantly reduces CMR acquisition time and the need for repeat scans while maintaining diagnostic accuracy, offering a more efficient workflow for challenging patients.
BACKGROUND A key cardiac magnetic resonance (CMR) challenge is breath-holding duration, difficult for cardiac patients. AIM To evaluate whether artificial intelligence-assisted compressed sensing CINE (AI-CS-CINE) reduces image acquisition time of CMR compared to conventional CINE (C-CINE). METHODS Cardio-oncology patients (n = 60) and healthy volunteers (n = 29) underwent sequential C-CINE and AI-CS-CINE with a 1.5-T scanner. Acquisition time, visual image quality assessment, and biventricular metrics (end-diastolic volume, end-systolic volume, stroke volume, ejection fraction, left ventricular mass, and wall thickness) were analyzed and compared between C-CINE and AI-CS-CINE with Bland–Altman analysis, and calculation of intraclass coefficient (ICC). RESULTS In 89 participants (58.5 ± 16.8 years, 42 males, 47 females), total AI-CS-CINE acquisition and reconstruction time (37 seconds) was 84% faster than C-CINE (238 seconds). C-CINE required repeats in 23% (20/89) of cases (approximately 8 minutes lost), while AI-CS-CINE only needed one repeat (1%; 2 seconds lost). AI-CS-CINE had slightly lower contrast but preserved structural clarity. Bland-Altman plots and ICC (0.73 ≤ r ≤ 0.98) showed strong agreement for left ventricle (LV) and right ventricle (RV) metrics, including those in the cardiac amyloidosis subgroup (n = 31). AI-CS-CINE enabled faster, easier imaging in patients with claustrophobia, dyspnea, arrhythmias, or restlessness. Motion-artifacted C-CINE images were reliably interpreted from AI-CS-CINE. CONCLUSION AI-CS-CINE accelerated CMR image acquisition and reconstruction, preserved anatomical detail, and diminished impact of patient-related motion. Quantitative AI-CS-CINE metrics agreed closely with C-CINE in cardio-oncology patients, including the cardiac amyloidosis cohort, as well as healthy volunteers regardless of left and right ventricular size and function. AI-CS-CINE significantly enhanced CMR workflow, particularly in challenging cases. The strong analytical concordance underscores reliability and robustness of AI-CS-CINE as a valuable tool.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: