Answers are grounded in this paper and cite their sources.
With the next generation of Human Epidermal Growth Factor Receptor 2 (HER2) -targeting therapies, such as antibody–drug conjugates, showing benefit in “HER2 low” and even “HER2 ultralow” patients, the need for novel methods to quantify HER2 expression accurately becomes even more important for clinical decision making. A HER2 PET/CT imaging assessment could evaluate HER2 positive disease locations while improving patient care, reducing the need for invasive biopsies. A single-domain antibody (sdAb)-based PET tracer could combine the high specificity of sdAbs with short-lived radionuclides such as fluorine-18 ( 18 F) and gallium-68 ( 68 Ga). SdAb-based PET tracers have clinically been used via a 68 Ga-chelator approach. However, the distribution of 68 Ga-labelled pharmaceuticals to peripheral PET centres is more challenging to organize due to the short half-life of 68 Ga, most certainly when the available activity is limited by a generator. Cyclotron produced 68 Ga has removed this limitation. Distribution of 18 F-labelled pharmaceuticals remains less challenging due to its slightly longer half-life, and radiofluorination of sdAbs via N -succinimidyl-4-[ 18 F]fluorobenzoate ([ 18 F]SFB) has shown to be a promising strategy for developing sdAb-based PET tracers. Although [ 18 F]SFB automation has been reported, automating protein conjugation proves challenging. Herein we report the fully automated, cartridge-based production of [ 18 F]FB-HER2 sdAb on a single synthesis module. [ 18 F]FB-HER2 sdAb (> 6 GBq) was obtained after a fully automated production (95 min), with a RCP > 95%, apparent molar activity > 20 GBq/µmol and decay-corrected radiochemical yield (RCY d.c.) of 14 ± 2% (n = 4). Further upscaling amounted to production batches of 16 GBq with an apparent molar activity > 40 GBq/µmol and RCY d.c. of 8 ± 1% (n = 4). Ex vivo biodistribution and PET imaging showed specific HER2-positive tumour targeting and low kidney retention. The [ 18 F]FB-HER2 sdAb tracer was produced with clinically relevant activities using a fully automated production method. The automated production method was designed to ease the translation to the clinic and has the potential to be used not only in mono-centre but also multi-centre clinical trials with one central production site. [ 18 F]FB-HER2 sdAb showed a favourable biodistribution pattern and could be a valuable alternative to 68 Ga-labelled sdAb-based PET tracers in the clinic.
No takes yet. Share an insight, caveat, or question.
Dierick et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: