Key result
Pressurized box plethysmography lowers flow cessation pressure to under ~10 mm Hg vs classical methods.
Answers are grounded in this paper and cite their sources.
Two techniques of venous occlusion pressure plethysmography were examined experimentally in the human upper limb. The first was the classical method, in which external pressure is applied to the limb solely by way of the plethysmograph. In the second, the entire upper limb including the plethysmograph and venous occlusion cuff was enclosed in a box within which the air pressure could be raised. For each method the predictability of perfusion pressure was estimated by measuring local tissue pressure, venous pressure and arterial pressure. Artifacts in the recording of blood flow were also sought. In the first method there was a nonuniform increase in tissue pressure, venous pressure and probably arterial pressure. The changes were uniform and predictable in the second. Flow cessation pressure was 19 to 36 mm Hg in the warm hand and 13 to 30 mm Hg in the forearm using the first method. It was less than 10 mm Hg with the other method. It is suggested that the second technique offers a method for reexamining pressure-flow relations in the human upper limb under more precisely controlled conditions than hitherto.
No takes yet. Share an insight, caveat, or question.
Ludbrook et al. (1967) studied this question. Venous occlusion pressure plethysmography with entire upper limb enclosed in a pressurized box vs. Classical venous occlusion pressure plethysmography was evaluated on Predictability of perfusion pressure and flow cessation pressure. Enclosing the upper limb in a pressurized box during plethysmography yielded uniform pressure changes and lower flow cessation pressure (<10 mm Hg vs 13-36 mm Hg with the classical method).
Synapse has enriched 10 related papers. Consider them for comparative context: