Answers are grounded in this paper and cite their sources.
Background/Aims Knee osteoarthritis is a common degenerative condition causing pain and reduced function, particularly in the medial compartment. Valgus unloader knee braces reduce knee adduction moment and improve symptoms, but inconsistent strap tension may limit efficacy. A biomechanical study identified 69 mmHg as a biomechanically effective strap pressure for reducing knee adduction moment while ensuring comfort. The aim of this study was to evaluate the clinical effectiveness of a valgus knee brace adjusted to 69 mmHg compared to conventional comfort-based adjustment in patients with medial knee osteoarthritis. Methods In a single-blind randomised controlled trial, 40 patients (aged 45–70 years, Kellgren-Lawrence grade II–III) with medial knee osteoarthritis were assigned to either the optimal tension group ( n =20, straps adjusted to 69 mmHg using a digital manometer) or the conventional group ( n =20, straps adjusted for comfort). Participants wore the brace for at least 4 hours a day for 6 weeks. Primary outcomes were pain (visual analogue scale) and function (Western Ontario and McMaster Universities Osteoarthritis Index). Satisfaction (Orthotics and Prosthetics Users' Survey) was the secondary outcome. Results Both groups showed significant reduction in pain ( P <0.01). The optimal tension group had a 48.5% reduction on the visual analogue scale (6.7 ± 1.2 to 3.4 ± 0.9) and the conventional group had a 45.3% reduction (6.6 ± 1.3 to 3.6 ± 1.0). Both groups had significant increases in function ( P <0.01). The optimal tension group improved by 10.2 points (47.8 ± 8.2 to 37.6 ± 7.1), and the conventional group by 9.8 points (48.0 ± 8.5 to 38.2 ± 7.4. Both groups reported high satisfaction (P =0.12) with the braces (optimal tension group: 4.5 ± 0.5; conventional group: 4.3 ± 0.6). There were no statistically significant differences between the two groups in pain ( P =0.21), function ( P =0.09), or satisfaction ( P =0.12) at 6 weeks. Conclusions Standardised 69 mmHg strap pressure produced clinical outcomes comparable to comfort-based adjustment over the short term. Further research is needed. Implications for practice Standardised strap pressure adjustment using a digital manometer can improve consistency and reproducibility of valgus knee brace fitting in clinical settings, particularly for less experienced clinicians. Clinicians should consider individual patient factors (skin condition, body mass index, activity level) when applying 69 mmHg pressure and monitor for skin tolerance
No takes yet. Share an insight, caveat, or question.
Khosravi et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: