Key result
Varying diastolic fitting alters excess pressure integral up to ~64% while reservoir parameters remain stable.
Why the study?
While the reservoir-wave concept remains debated, there is no consensus on the best fitting method for calculating the reservoir pressure waveform.
Does varying the diastolic pressure decay fitting technique (degrees of freedom and fitting window length) affect calculated reservoir-wave hemodynamic parameters, wave speed, and wave intensity parameters in healthy middle-aged adults?
Cross-Sectional (n=1,037)
No
Does varying the diastolic pressure decay fitting technique (degrees of freedom and fitting window length) affect calculated reservoir-wave hemodynamic parameters, wave speed, and wave intensity parameters in healthy middle-aged adults?
Peak reservoir pressure, reservoir pressure time integral, and wave speed are robust against variations in diastolic pressure decay fitting methods, making them more reliable non-invasive vascular diagnostic indicators than excess pressure, velocity, and wave intensity parameters.
Answers are grounded in this paper and cite their sources.
Reservoir pressure metrics remain stable across fitting methods; leaves open their preferential use as reliable non-invasive vascular indicators.
The reservoir-wave model assumes that the measured arterial pressure is made of two components: reservoir and excess. The effect of the reservoir volume should be excluded to quantify the effects of forward and backward traveling waves on blood pressure. Whilst the validity of the reservoir-wave concept is still debated, there is no consensus on the best fitting method for the calculation of the reservoir pressure waveform. Therefore, the aim of this parametric study is to examine the effects of varying the fitting technique on the calculation of reservoir and excess components of pressure and velocity waveforms. Common carotid pressure and flow velocity were measured using applanation tonometry and doppler ultrasound, respectively, in 1037 healthy humans collected randomly from the Asklepios population, aged 35 to 55 years old. Different fitting techniques to the diastolic decay of the measured arterial pressure were used to determine the asymptotic pressure decay, which in turn was used to determine the reservoir pressure waveform. The corresponding wave speed was determined using the PU-loop method, and wave intensity parameters were calculated and compared. Different fitting methods resulted in significant changes in the shape of the reservoir pressure waveform; however, its peak and time integral remained constant in this study. Although peak and integral of excess pressure, velocity components and wave intensity changed significantly with changing the diastolic decay fitting method, wave speed was not substantially modified. We conclude that wave speed, peak reservoir pressure and its time integral are independent of the diastolic pressure decay fitting techniques examined in this study. Therefore, these parameters are considered more reliable diagnostic indicators than excess pressure and velocity which are more sensitive to fitting techniques.
No takes yet. Share an insight, caveat, or question.
Pomella et al. (2020) conducted a cross-sectional in Healthy humans free from manifest cardiovascular disease (n=1,037). Diastolic pressure decay fitting techniques for the reservoir-wave model (varying degrees of freedom [2 DOF vs 3 DOF] and diastolic fitting window length [whole diastole vs last two-thirds of diastole]) vs. Comparison across four fitting combinations (3 DOF whole, 2 DOF whole, 3 DOF 2/3, 2 DOF 2/3) and measured PU-loop vs excess PexUex-loop was evaluated on Sensitivity of reservoir pressure parameters (Prmax, PRI), excess pressure/velocity parameters (Pexmax, PEI, Uexmax), wave speed, and wave intensity parameters (FCW, BCW, FEW) to diastolic fitting technique (p=<0.05). Varying diastolic pressure decay fitting techniques left peak reservoir pressure (≤6% change), its integral (≤3%), and wave speed (≤8%) largely stable, while altering excess pressure integral up to 64%.
Synapse has enriched 10 related papers. Consider them for comparative context: