Key result
The proposed feature fusion and three-point SPD-RANSAC model fitting method segmented catheters in 3-D ultrasound images with an average tip-point error of 1.9 mm, which is smaller than the catheter diameter.
Why the study?
Catheter identification in 3-D ultrasound is challenging due to limited spatial resolution and complex cardiac anatomy, requiring automated segmentation methods to aid interventions.
An automated catheter segmentation method using feature fusion and model fitting achieves sub-diameter accuracy in 3-D ultrasound images, potentially facilitating image-guided cardiac interventions.
Answers are grounded in this paper and cite their sources.
Promising for preclinical cardiac intervention models; leaves open human validation before clinical 3-D ultrasound use.
Ultrasound (US) has been increasingly used during interventions, such as cardiac catheterization. To accurately identify the catheter inside US images, extra training for physicians and sonographers is needed. As a consequence, automated segmentation of the catheter in US images and optimized presentation viewing to the physician can be beneficial to accelerate the efficiency and safety of interventions and improve their outcome. For cardiac catheterization, a three-dimensional (3-D) US image is potentially attractive because of no radiation modality and richer spatial information. However, due to a limited spatial resolution of 3-D cardiac US and complex anatomical structures inside the heart, image-based catheter segmentation is challenging. We propose a cardiac catheter segmentation method in 3-D US data through image processing techniques. Our method first applies a voxel-based classification through newly designed multiscale and multidefinition features, which provide a robust catheter voxel segmentation in 3-D US. Second, a modified catheter model fitting is applied to segment the curved catheter in 3-D US images. The proposed method is validated with extensive experiments, using different in-vitro, ex-vivo, and in-vivo datasets. The proposed method can segment the catheter within an average tip-point error that is smaller than the catheter diameter (1.9 mm) in the volumetric images. Based on automated catheter segmentation and combined with optimal viewing, physicians do not have to interpret US images and can focus on the procedure itself to improve the quality of cardiac intervention.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2019) studied Cardiac catheterization (image processing) (n=50). Feature fusion and modified SPD-RANSAC model fitting vs. Two-point RANSAC model fitting was evaluated on Average tip-point error (mm). The proposed feature fusion and three-point SPD-RANSAC model fitting method segmented catheters in 3-D ultrasound images with an average tip-point error of 1.9 mm, which is smaller than the catheter diameter.